Sharp Air Conditioner Error Codes

 Sharp Air Conditioner Error Codes:

Sharp Air Conditioner Error Codes
Sharp Air Conditioner Error Codes
Error CodesProblem
EEButtons are locked
E0Water pump malffunction
E1High pressure protection of compressor
E2Indoor anti-frozen of compressor
E3Low pressure protection of compressor
E4Air discharge high-temperature protection of compressor
E5Overload protection of compressor
E6Transmit malfunction
E8Indoor fan protection
E9Water flow protection
FFConnected control communications Failure
F0Malfunction of indoor environment sensor at air return vent
F1Evaporator sensor malfunction
F2Condenser sensor malfunction
F3Outdoor environment sensor malfunction
F4Malfunction of air discharge sensor
F5Malfunction of environment sensor on displayer
eeMalfunction of outdoor drive memory chip. Outdoor drive board.
H3
Compressor over load protection. Compressor overload switch.
H4Overload protection. Evaporator temperature, condenser temperature.
H6
Malfunction of outdoor fan motor. Outdoor fan motor.
U7Direction changing malfunction of 4-way valve.
P6Communicatio n malfunction between main control and drive.
EEMalfunction of outdoor main control memory chip. Outdoor main control board.

ES: If this display reads ”ES” or ”AS”, a sensor has failed. Contact your Authorized Sharp Service Center.

Sharp Air Conditioner Remote Control
”ES” or ”AS”, a sensor has failed

Sharp Air Conditioner Troubleshooting

SymptomTroubleshooting
Air conditioner does not run if attem pt to immediately restart after a stop.To protect the air conditioner upon immediate restart after a stop, the microcomputer controller will delay the unit for 3 minutes before the air conditioner will run.
Air conditioner blows out bad smell when it is initially started.The air conditioner itself has no bad smell. If a bad smell has been accumulated from the environment, clean the airfilter.
You may hear ''Water Flowing'' noiseWhen the air conditioner is started, or the compressor is started or stopped during running or the air conditioner is stopped, sometimes you may hear fluid gurgling noises. This is not a fault - it is the sound offlowing refrigerant.
Sometimes a thin mist will flow out of the outlet when air conditioner is running under cooling mode.This might occur when indoor temperature and humidity are high. This is because the indoor air is quickly cooled down. After a period of time, the mist will disappear with the decrease of indoor temperature and humidity.
You may hear a slight cracking sound when the air conditioner is started or stopped.This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
The unit will not runHas the power been shut down? Has the circuit breaker device tripped off? Is the Timer correctly used? Have the wiring or connections been a damaged?P
Cooling (Heating) efficiency is not good.Is Temp. setting suitable? Are inlet and outlet vents obstructed? Are the windows and doors closed? Is the fa n speed_set at low speed? Is there too much dust accumulated and obstructing the filter?
Wireless remote control is not workingCheck that there is no magnetic or electrical interference near the main unit that may be affecting the operation of the controller.
Water is dripping or leaking from the indoor unitThe air humidity is on the high side. Condensing water has overflowed. The connection of indoor unit drainage pipe has been loosened.
Noise from indoor unitFan or compressor relay is switching on or off. When defrosting is started or stopped, there is a sound of refrigerant flowing in the reverse direction.
Moisture on air outlet ventIf unit is running under high humidity for a long time, moisture will be condensed on the air outlet grill and may drip off.
Sharp Air Conditioner Remote Control
Sharp Air Conditioner Remote Control

Main board dual 8 numeral tube Display Codes for Outdoor Unit of 09~48k

Malfunction ItemIndoor-Outdoor Unit Display
DC busbar over-voltage protectionPH
IPM or PFC over-temperature protectionP8
Current sense circuit errorPc
IPM or PFC temperature sensor errorP7
Compressor current protectionP5
DC busbar under-voltage protectionPL
Compressor startup failureLc
Drive module resetP0
Compressor motor desynchronizingH7
Phase lossLd
Drive-to-main-control communication errorP6
IPM protectionH5
Compressor overload protectionH3
AC current protection (input side)PA
Charging circuit errorPU
PFC protectionHC(48k only)
DC fan errorH6
Input AC voltage abnormalityPP
Driving board memory chip erroree(09-42k)

Sharp Air Conditioner Manual PDF

Sharp Air Conditioner Service Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

Innovair Air Conditioner Error Codes

 innovair  prestige  inverter mini split system: Innovair Air Conditioner Error Codes Error Codes Problem E2 Anti-freezing protection E3 Block or Low pressure of refrigerant system E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor unit and outdoor unit E8 Anti-high temperature protection H4 Anti-high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection LP Indoor unit and outdoor unit doesn't match L3 Outdoor DC fan motor malfunction L9 Power protection Fo Gathering refrigerant F1 Indoor ambient sensor open or short circuit F2 Indoor tube sensor open or short circuit F3 Outdoor ambient sensor open or short circuit F4 Outdoor tube sensor open or short circuit F5 Exhaust sensor open or short circuit F6 Overload limit / drop frequency F8 Over current limit / drop frequency F9 High exhaust temperature limit / drop frequency F0 Refrigerant leakage protection FH Anti-f...