innovair prestige inverter mini split system:
![Innovair Air Conditioner Error Codes](https://acerrorcode.com/wp-content/uploads/2019/05/Innovair-Air-Conditioner-Error-Codes.jpg)
Error Codes | Problem |
---|---|
E2 | Anti-freezing protection |
E3 | Block or Low pressure of refrigerant system |
E4 | Compressor exhaust high temperature protection |
E5 | AC over-current protection |
E6 | Communication failure between indoor unit and outdoor unit |
E8 | Anti-high temperature protection |
H4 | Anti-high temperature protection |
H6 | No feedback of indoor fan motor |
C5 | Jumper cap malfunction protection |
LP | Indoor unit and outdoor unit doesn't match |
L3 | Outdoor DC fan motor malfunction |
L9 | Power protection |
Fo | Gathering refrigerant |
F1 | Indoor ambient sensor open or short circuit |
F2 | Indoor tube sensor open or short circuit |
F3 | Outdoor ambient sensor open or short circuit |
F4 | Outdoor tube sensor open or short circuit |
F5 | Exhaust sensor open or short circuit |
F6 | Overload limit / drop frequency |
F8 | Over current limit / drop frequency |
F9 | High exhaust temperature limit / drop frequency |
F0 | Refrigerant leakage protection |
FH | Anti-freezing limit / drop frequency |
H1 | Defrosting |
H3 | Compressor overload protection |
H5 | IPM protection |
H5 | Module temperature is too high |
HC | PFC protection |
EE | Loading EEPROM malfunction |
PH | High PN voltage protection |
PL | Low PN voltage protection |
U7 | 4-way valve reversal abnormal |
d1/d2/d3 | DRED1 / DRED2 / DRED3 |
P0 | Compressor Min frequence in test state |
P1 | Compressor rated frequence in test state |
P2 | Compressor maximum frequence in test state |
P3 | Compressor intermediate frequence in test state |
EU | Frequency limiting (module temperature ) |
LU | Frequency limiting (power) |
JF | Malfunction of detecting plate (WIFI ) |
F0 | Insufficient fluorine protection |
innovair nature inverter mini split system:
![Innovair Mini Split AC Error Codes](https://acerrorcode.com/wp-content/uploads/2019/05/Innovair-Mini-Split-AC-Error-Codes.jpg)
Error Codes | Problem |
---|---|
E0 | Indoor unit EEPROM parameter error |
E1 | Indoor / outdoor units communication error |
E2 | Zero-crossing signal detection error |
E3 | Indoor fan speed has been out of control |
E4 | Indoor room temperature sensor T1 open circuit or short circuit |
E5 | Evaporator coil temperature sensor T2 open circuit or short circuit |
EC | Refrigerant leakage detection |
F1 | Outdoor temperature sensor T4 open circuit or short circuit |
F2 | Condenser coil temperature sensor T3 open circuit or short circuit |
F3 | Compressor discharge temperature sensor T5 open circuit or short circuit |
F4 | Outdoor unit EEPROM parameter error |
P0 | IPM malfunction or IGBT over-strong current protection |
P1 | Over voltage or over low voltage protection |
P4 | Inverter compressor drive error |
Diagnosis and Solution – How to Fix?
Error Code: E0/F4
EEPROM parameter error diagnosis and solution (E0/F4)
Malfunction decision conditions: Indoor or outdoor PCB main chip does not receive feedback from EEPROM chip.
Supposed causes: Installation mistake, PCB faulty.
Error Code: E1
Indoor / outdoor unit’s communication diagnosis and solution (E1)
Malfunction decision conditions: Indoor unit does not receive the feedback from outdoor unit during 110 seconds and this condition happens four times continuously.
Supposed causes: Wiring mistake, Indoor or outdoor PCB faulty.
Error Code: E2
Zero crossing detection error diagnosis and solution (E2)
Malfunction decision conditions: When PCB does not receive zero crossing signal feedback for 4 minutes or the zero crossing signal time interval is abnormal.
Supposed causes: Connection mistake, PCB faulty.
Error Code: E3
Fan speed has been out of control diagnosis and solution (E3)
Malfunction decision conditions: When indoor fan speed keeps too low (300RPM) for certain time, the unit will stop and the LED will display the failure.
Supposed causes: Wiring mistake, Fan ass’y faulty, Fan motor faulty, PCB faulty.
Error Code: E5
Open circuit or short circuit of temperature sensor diagnosis and solution (E5)
Malfunction decision conditions: If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED will display the failure.
Supposed causes: Wiring mistake, Sensor faulty.
Error Code: EC
Refrigerant Leakage Detection diagnosis and solution (EC)
Malfunction decision conditions: Define the evaporator coil temp.T2 of the compressor just starts running as Tcool. In the beginning 5 minutes after the compressor starts up, if T2 <Tcool-2℃ does not keep continuous 4 seconds and this situation happens 3 times, the display area will show “EC” and AC will turn off.
Supposed causes: T2 sensor faulty, Indoor PCB faulty, System problems, such as leakage or blocking.
Error Code: P0
IPM malfunction or IGBT over-strong current protection diagnosis and solution (P0)
Malfunction decision conditions: When the voltage signal that IPM send to compressor drive chip is abnormal, the display LED will show “P0” and AC will turn off.
Supposed causes: Wiring mistake; IPM malfunction; Outdoor fan ass’y faulty Compressor malfunction; Outdoor PCB faulty.
Error Code: P1
Over voltage or too low voltage protection diagnosis and solution (P1)
Malfunction decision conditions: An abnormal voltage rise or drop is detected by checking the specified voltage detection circuit.
Supposed causes: Power supply problems, System leakage or block, PCB faulty.
Error Code: P2
High temperature protection of compressor top diagnosis and solution (P2)
Malfunction decision conditions: If the sampling voltage is not 5V, the LED will display the failure.
Supposed causes: Power supply problems, System leakage or block, PCB faulty.
Error Code: P4
Inverter compressor drive error diagnosis and solution (P4)
Malfunction decision conditions: An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage detection, compressor rotation speed signal detection and so on.
Supposed causes: Wiring mistake; IPM malfunction; Outdoor fan ass’y faulty Compressor malfunction; Outdoor PCB faulty.
Comments