Skip to main content

Sea Breeze AC Mini Split Error Codes

 This air conditioning system has been provided with built in self diagnostic error codes. Please refer to the following table for error code definitions:

Sea Breeze AC Mini Split Error Codes
Sea Breeze AC Mini Split Error Codes

For Sea Breeze Models: 9MH46ZIGX Evaporator- 12MH46ZIGX Evaporator- 18MH46ZIGX Evaporator- 34MH46ZOGX Condenser – 24MH46ZOGX Condenser

Indoor Unit Error Codes:

Error CodesMeaning
H4System Overload
H3Compressor Overload Protection
H5IPM Protection
E1High Pressure Protection
E2Anti-Freezing Protection
E4Exhaust Protection
E5Over Current Protection
E7Mode Conflict
E6Communication Malfunction
H1Defrost or Oil Return of Heat
F1Indoor Ambient Sensor Malfunction
F2Indoor Tube Sensor Malfunction
F3Outdoor Ambient Sensor Malfunction
F4Outdoor Tube Sensor Malfunction
F5Outdoor Exhaust Sensor Malfunction
H7Failure Startup
HCPFC Malfunction PFC
HEDemagnetizing Protection for Compressor
F6Frequency Drop for Overload
F8Frequency Drop for Over Current Protection
F9Frequency Drop for Exhaust Protection
H0Frequency Drop for Heating High Temperature Protection
E9Anti-Cold Protection
F7Oil Return of Cooling

Troubleshooting

The first step in troubleshooting is to disconnect power for 30 seconds to allow the unit to reset. If this does not rectify the problem proceed with the troubleshooting chart below.

Problem: The unit does not run.

Troubleshooting:

  • Is the power off?
  • Is the circuit protection device tripped?
  • Is voltage too high or low? (Tested by a professional)
  • Is the Timer on?
  • A 3 minute delay occurs before each compressor start.

Problem: Cooling and or Heating efficiency is not good.

Troubleshooting:

  • Is temperature setting correct?
  • Are the inlet or outlet vents obstructed?
  • Is the filter clean?
  • Are windows and doors closed?
  • Is fan set to low speed?
  • Is there a heat source in the room?

Problem: Wireless remote control is not working.

Troubleshooting:

  • Reset unit. Disconnect main power for 30 seconds then reapply.
  • Is it within receiving range? Is it obstructed?
  • Replace the batteries.
  • Is remote control damaged?

Problem: Water leaking into room.

Troubleshooting:

  • The air humidity is excessively high. Check to see if all windows and doors are closed.
  • Call service Tech if not corrected by the above action.

Problem: Water leakage in outdoor unit.

Troubleshooting:

  • When the unit is running in Auto Defrosting mode, ice will thaw and drip into pan.
  • When the unit is running in HEAT mode, the water adhered to the condenser coil drains into pan.

Problem: Noise from indoor unit emitted.

Troubleshooting:

  • When defrosting is started or stopped, it will make a sound. This is due to the refrigerant flow reversing directions.
  • Normal refrigerant flowing in unit.

Notes:

  1. If E7 error code occurs, see the AUTO mode section in Operators Manual on page 7 .
  2. An audible beep will be heard, when a button is pressed, if the remote control is communicating with the receiver.

Selecting locations for the Indoor unit

  1. Determine the best location for mounting the Indoor unit. Ensure the dimensions requirement indicated be the arrows are followed.
  2. Paying close attention to the air circulation in the room, these units throw air approximately 15ft. Ensure that no obstacles impede airflow.
  3. Do not mount this unit close to a heat source or a doorway.
Best Location For Ac Unit In Your Room
Best Location For Ac Unit In Your Room

Selecting location for Outdoor unit

  1. Determine the best location for mounting the outdoor unit. Ensure the dimensions requirement indicated be the arrows are followed.
  2. Do not mount this unit close to combustibles or heat sources.
  3. Although this unit is fairly quiet when in operation, do not mount where noise issues could be a problem.

Sea Breeze AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive load on the board. Problem:  NO

York VRF Error Codes

  Malfunction and Protection Code Table. The display board in digital scroll system is just to display running conditions and  malfunction information. The manual button is just to check the address code and power code  of indoor units. York VRF Error Codes Malfunction and Protection Code Table: Error Codes Contents E0 Phase sequence or lack of phase E1 Communication malfunction E2 T1 sensor malfunction E3 T2A sensor malfunction E4 T2B sensor malfunction E5 T3 sensor malfunction E6 Over-zero checking malfunction E7 EEPROM malfunction E8 Fan motor checking out of control E9 Communication malfunction between PCB and Display board EF Other malfunction EE Water level checking malfunction ED Outdoor protection EC Clear malfunction EB Inverter Module Protection EA Compressor Over-current (4 times) P0 Evaporator Temp. Protection P1 Anti-cooling or Defrost Protection P2 Condenser High Temp. Protection P3 Compressor Temp. Protection P4 Discharge Pipe Temp. Protection P5 Discharge High-pressure