Skip to main content

Midea Portable Air Conditioner Error Codes

 

Midea Portable Air Conditioner Error Codes
Midea Portable Air Conditioner Error Codes
Error CodesCause
E1Room temperature sensor error- Unplug the unit and plug it back in. If error repeats, call for service
E2Evaporator temperature sensor error- Unplug the unit and plug it back in. If error repeats, call for service.
E4Display panel communication error- Unplug the unit and plug it back in. If error repeats, call for service.
E5The auto sliding panel malfunction- Unplug the unit and plug it back in. If error repeats, call for service.
E0Unit malfunction- Unplug the unit and plug it back in. If error repeats, call for service.

INDICATOR LIGHTS display

  • lights up when the POWER is on.
  • lights up when LOCK function is set.
  • lights up when TIMER ON function is set.
  • lights up when TIMER OFF function is set.
  • lights up when FOLLOW ME function is set.
  • lights up when SLEEP function is set.
  • lights up when FRESH function is set by remote controller.

Midea Portable Air Conditioner Troubleshooting

Please check the machine according to the following form before asking for maintenance:

Problem: Unit does not turn on when pressing ON/ OFF button

Possible Cause:

  1. P1 Error Code.
  2. In COOL mode: room temperature is lower than the set temperature.

Troubleshooting:

  1. The water collection tray is full. Turn off the unit, drain the water from the water collection tray and restart the unit.
  2. Reset the temperature.

Problem: Unit does not cool well

Possible Cause:

  1. The air filter is blocked with dust or animal hair.
  2. Exhaust hose is not connected or is blocked.
  3. The unit is low on refrigerant.
  4. Temperature setting is too high.
  5. The windows and doors in the room are open.
  6. The room area is too large.
  7. There are heat sources inside the room.

Troubleshooting:

  1. Turn off the unit and clean the filter according to instructions.
  2. Turn off the unit, disconnect the hose, check for blockage and reconnect the hose.
  3. Call a service technician to inspect the unit and top off refrigerant.
  4. Decrease the set temperature.
  5. Make sure all windows and doors are closed.
  6. Double-check the cooling area.
  7. Remove the heat sources if possible.

Problem: The unit is noisy and vibrates too much

Possible Cause:

  1. The ground is not level.
  2. The air filter is blocked with dust or animal hair.

Troubleshooting:

  1. Place the unit on a flat, level surface.
  2. Turn off the unit and clean the filter according to instructions.

Problem: The unit makes a gurgling sound

Possible Cause: This sound is caused by the flow of refrigerant inside the unit

Troubleshooting: This is normal.

Midea Portable Air Conditioner Troubleshooting
Midea Portable Air Conditioner Troubleshooting

Clean the Air Filter

  • Be sure to clean the air filter every 2 weeks for optimal performance.
  • The water collection tray should be drained immediately after P1 error occurs, and before storage to prevent mold.
  • In households with animals, you will have to periodically wipe down the grill to prevent blocked airflow due to animal hair.
Midea Portable AC Clean the Air Filter
Midea Portable AC Clean the Air Filter

 

Midea Portable Air Conditioner
Midea Portable Air Conditioner

Midea Portable Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...