McQuay Rooftop Package AC Error Codes

 When the system is on and an error occurs, the ON/OFF LED on the LCD panel will blink and an error code is shown. When the system is off and there is a thermistor error, the ON/OFF LED is off but the error code is still displayed. Each error code represents different message as below.

McQuay Rooftop Packaged AC Error Code
Error CodesPossible Fault
E01Require manual reset (possible causes)
E02Compressor 1 high temperature (overload)
E03Compressor 2 high temperature(overload)
E06Compressor 1 high pressure trip / contact open
E07Compressor 2 high pressure trip / contact open
E10Compressor 1 trip / low R-22 / outdoor abnormal
E11Compressor 2 trip / low R-22 / outdoor abnormal
E14Room sensor short
E15Room sensor open
E16Indoor coil sensor 1 short
E17Indoor coil sensor 2 short
E20Indoor coil sensor 1 open
E21Indoor coil sensor 2 open
E24Outdoor coil sensor 1 short
E25Outdoor coil sensor 2 short
E28 Outdoor coil sensor 1 open
E29Outdoor coil sensor 2 open
E32Compressor 1 de-ice
E33Compressor 2 de-ice

 

McQuay Rooftop Packaged Sequential Controller Functions

 

McQuay Rooftop Packaged AC Error Code
McQuay Rooftop Packaged AC Error Codes

Features

  • High Efficiency: The McQuay rooftop unit is supplied with high efficiency and reliable scroll compressor (except MRT 080/100/150/200 AR).
  • Package Unit: Dubbed the “Plug and Play” equivalent in the air-conditioning industry, the single unit configuration allows hassle free installation. No additional piping work is required as both the indoor and outdoor sides are pre-connected. Refrigerant is factory pre-charged to ensure clean and efficient operation.
  • Flexibility Of Air Supply: McQuay rooftop unit uses a belt driven fan such that the air volume and static required can be adjusted according to the requirement. This flexibility allows for wider application.
  • Flat Top Design: McQuay rooftop unit’s flat top design allows for maximum utilization of warehouse and container space.
  • Electrical Control Capability: All series are equipped with our Electronic Remote Controller (SLM and Sequential LCD). The Sequential LCD features 7 days programmable timer, compressor run/error status, cool/heat/fan/dry/auto modes, etc, while the SLM features a 15 hour delay timer, cool/heat/fan/dry/auto modes, etc. Part loading of system capacity is now possible with the use of our Sequential PAC (Package Air-Condition) control for multiple compressor McQuay rooftop units (M(4)RT150/200/250/300/360/420 A/AR).

McQuay Rooftop Packaged AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...