Logik Portable Air Conditioner Error Codes

 

Logik Portable Air Conditioner Error Codes
Logik Portable Air Conditioner Error Codes
LED DisplayDescription
E1 Internal malfunction. Switch off the unit. Unplug and re-plug the unit. If the error persists, call for a qualified service agent for assistance.
E2Internal malfunction. Switch off the unit. Unplug and re-plug the unit. If the error persists, call for a qualified service agent for assistance.
E4Internal malfunction. Switch off the unit. Unplug and re-plug the unit. If the error persists, call for a qualified service agent for assistance.
P1Drain the water. Please refer to the section “Draining the Water”.
Logik Portable Air Conditioner Fault Codes List
Logik Portable Air Conditioner Fault Codes List

LOGIC Portable Air Conditioner Troubleshooting

LOGIC Portable Air Conditioner Troubleshooting
LOGIC Portable Air Conditioner Troubleshooting

Problem: Unit does not start or there is no power when pressing on the unit or ON/OFF on the remote control.

Solution:

  • Check that the unit is firmly plugged in and the mains socket is switched on.
  • Set a different temperature.
  • Drain the water from the Bottom Tray Drain Outlet.

Problem: Room is not cool enough

Solution:
  • Check that all windows and doors are closed.
  • Remove or switch off all heat sources if possible.
  • Check that the exhaust air duct is connected properly and not blocked. If blocked, clean and re-connect.
  • Clean the air filter and re-fit securely before continuing operation.
  • Lower the temperature.

Problem: Noisy or excessive vibration

Solution:  Move the unit to a stable, flat and level surface

Problem: Gurgling is heard.

Solution: This is normal; it should not be considered a fault.

If problem(s) persists, contact a qualified service agent for assistance.

Logik Portable Air Conditioner Remote Control
Logik Portable Air Conditioner Remote Control

Draining the Water

When the LED display shows “P1”, it means the bottom tray is full of water and needs draining. The unit will stop automatically and cannot be started until the water is drained.

  1. Move the unit to a drain location.
  2. Remove the bottom tray drain outlet cover and plug.
  3. After the water is fully drained, replace the plug and cover.
  4. Switch on the unit until “P1” disappears.

If “P1” continues to display, unplug the unit and call for a qualified service agent for assistance.

Logik Portable Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...