Lloyd Air Conditioner Error Codes

 If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident, investigate the system according to the following procedures.

Lloyd Air Conditioner Error Codes
Lloyd Air Conditioner Error Codes

Troubles and Causes of Remote Controller;

Before asking for serving or repairing, check the following points.

Error CodesMalfunction
E2Room temperature sensor checking channel is abnormal. LED 2 Timer: Flashing
E3Pipe temperature sensor checking channel is abnormal. LED 1 Operation: Flashing
E4Outdoor pipe TEMP. sensor checking is abnormal. LED 3 Def.Fan: Flashing
E6Outdoor malfunction. LED 1, LED 2, LED 3, LED 4 : Flashing
E7EEPROM malfunction. LED 1, LED 2 : Flashing
E8Water-level alarm malfunction. LED 4 Alarm: Flashing
CLCL is not actually a fault code. it is an indication that the child lock is activated.
DFThe df fault code signals a defrost mode issue.
H3The h3 fault code indicates a compressor overload protection issue.
P3Lack of gas in the system or the pcb is miscalculating the gas pressure.
P4When the indoor unit displays an P4 error on temperature indicator, it means there is an inverter compressor drive error.
Four-way Cassette Type Air Conditioner E2-E3-E4-E6-E7-E8
Four-way Cassette Type Air Conditioner E2-E3-E4-E6-E7-E8

Troubles and causes of air conditioner

If one of the following malfunctions occur, stop operation, shut off the power, and contact with your dealer.

    • The operation lamp is flashing rapidly (5Hz). This lamp is still flashing rapidly after turn off the power and turn on again.
    • Remote controller receives malfunction or the button does not work well.
    • A safety device such as a fuse, a breaker frequently actuates.
    • Obstacles and water enter the unit.
    • Water leaks from indoor unit.
    • Other malfunctions.

Troubleshooting

Symptoms: Unit does not start

Causes:

      1. Power failure.
      2. Power switch is off.
      3. Fuse of power switch may have burned.
      4. Batteries of remote controller exhausted or other problem of controller.

Solution:

      1. Wait for the comeback of power.
      2. Switch on the power.
      3. Replace the fuse.
      4. Replace the batteries or check the controller.

Symptoms: Units start or stop frequently

Causes:

      1. Refrigerant is too little or too much.
      2. Air or no concreting gas in the refrigerating circuit.
      3. Compressor is malfunction.
      4. Voltage is too high or too low.
      5. System circuit is blocked.

Solution:

      1. Check leakage, and rightly recharge refrigerant.
      2. Vacuum and recharge refrigerant.
      3. Maintenance or change compressor.
      4. Install manostat.
      5. Find reasons and solution.

Symptoms: Low cooling effect

Causes:

      1. Outdoor unit and indoor unit heat exchanger is dirty.
      2. The air filter is dirty.
      3. Inlet/outlet of indoor/outdoor units is blocked.
      4. Doors and windows are open
      5. Sunlight directly shine.
      6. Too much heat resource.
      7. Outdoor temp. is too high.
      8. Leakage of refrigerant or lack of refrigerant.

Solution:

      1. Clean the heat exchanger.
      2. Clean the air filter.
      3. Eliminate all dirties and make air smooth.
      4. Close doors and windows.
      5. Make curtains in order to shelter from sunshine.
      6. Reduce heat source.
      7. AC cooling capacity reduces (normal).
      8. Check leakage and rightly recharge refrigerant.

Symptoms: Low heating effect

Causes:

      1. Outdoor temperature is lower than 7 C .
      2. Doors and windows not completely closed.
      3. Leakage of refrigerant or lack of refrigerant.

Solution:

      1. Use heating device.
      2. Close doors and windows.
      3. Check leakage and rightly recharge refrigerant.

Symptoms: The fan speed can not be changed.

Causes:

      1. Check whether the MODE indicated on the display is “AUTO”
      2. Check whether the MODE indicated on the display is “DRY”

Solution:

      1. When the automatic mode is selected, the air conditioner will automatically change the fan speed.
      2. When dry operation is selected, the air conditioner automatically change the fan speed. The fan speed can be selected during “COOL” , “FAN ONLY”, and “HEAT”.

 

Lloyd-Air-Conditioner-Error-Code
Lloyd Air Conditioner Error Code
Lloyd-Air-Conditioner-Error-CodeS
Lloyd Air Conditioner Error Codes

Symptoms: The remote controller signal is not transmitted even when the ON/OFF button is pushed.

Causes: Check whether the batteries in the remote controller are exhausted.

Solution: The power supply is off.

Symptoms: The TEMP. indicator does not come on.

Causes: Check whether the MODE indicated on the display is FAN ONLY.

Solution: The temperature cannot be set during FAN mode.

Symptoms: The indication on the display disappears after a lapse of time.

Causes: Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display.

Solution: The air conditioner operation will stop up to the set time.

Symptoms: The TIMER ON indicator goes off after a lapse of certain time.

Causes: Check whether the timer operation is started when the TIMER ON is indicated on the display.

Solution: Up to the set time, the air conditioner will automatically start and the appropriate indicator will go off.

Symptoms: No receiving tone sounds from the indoor unit even when the ON/OFF button is pressed.

Causes: Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON/OFF button is pressed.

Solution: Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit, and then repeatly push the ON/OFF button twice.

 Lloyd Air Conditioner  Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

Innovair Air Conditioner Error Codes

 innovair  prestige  inverter mini split system: Innovair Air Conditioner Error Codes Error Codes Problem E2 Anti-freezing protection E3 Block or Low pressure of refrigerant system E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor unit and outdoor unit E8 Anti-high temperature protection H4 Anti-high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection LP Indoor unit and outdoor unit doesn't match L3 Outdoor DC fan motor malfunction L9 Power protection Fo Gathering refrigerant F1 Indoor ambient sensor open or short circuit F2 Indoor tube sensor open or short circuit F3 Outdoor ambient sensor open or short circuit F4 Outdoor tube sensor open or short circuit F5 Exhaust sensor open or short circuit F6 Overload limit / drop frequency F8 Over current limit / drop frequency F9 High exhaust temperature limit / drop frequency F0 Refrigerant leakage protection FH Anti-f...