Lennox Rooftop-Gas Furnace Error Codes

 Climatic 50 Roof-Top, Aircoolair & Compactair Version 24

Lennox Rooftop-Gas Furnace Error Codes
Lennox Rooftop-Gas Furnace Error Codes
Error CodesProblem
001Airflow
004Filters, Clogged up
005Filters, Missing
006Recovery Module , Filters, Clogged up
011Electric heating elements
012High Temperature, Blowing
013Low Temperature, Ambient
014Gas burner, 1
015Gas burner, 2
022Low Temperature, Blowing
023High Temperature, Ambient
031Humidifier
032Low Humidity, Ambient
033High Humidity, Ambient
041Pump
051Recovery Module, Motor failure
052Recovery Module, Wheel failure
070Clock card
071BE50, 1
072BE50, 2
081Temperature sensor, Ambient
082Humidity sensor, Ambient
083Temperature probe, Outside
084Humidity sensor, Outside
085Temperature probe, Blower
086Circuit 1, Temperature sensor, Water condenser Outlet
087Circuit 2, Temperature sensor, Water condenser Outlet
088Temperature sensor, return or Mixing air
091Blower
092Circuit 1, Condenser fan
093Circuit 2, Condenser fan
094Circuit 3, Condenser fan
095Circuit 4, Condenser fan
096Low temperature, Water Condenser
097High temperature, Water Condenser
098Flow rate, water condenser
099Smoke detector
111Circuit 1, Probe or Sensor
115Circuit 1, High pressure or electrical protection
117Circuit 1, Low pressure
118Circuit 1, Risk of Frosting
121Circuit 2, Probe or Sensor
125Circuit 2, High pressure or electrical protection
127Circuit 2, Low pressure
128Circuit 2, Risk of Frosting
131Circuit 3, Probe or Sensor
135Circuit 3, High pressure or electrical protection
137Circuit 3, Low pressure
141Circuit 4, Probe or Sensor
145Circuit 4, High pressure or electrical protection
147Circuit 4, Low pressure

Lennox Gas Furnace Error Codes

Lennox Gas Furnace Error Codes
Lennox Gas Furnace Error Codes

EL180DFE series units are mid-efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok heat exchangers formed of aluminized steel. EL180DFE units are available in heating capacities of 44,000 to 110,000 Btuh and cooling applications 1.5 to 5 tons. Refer to Engineering Handbook for proper sizing.

The integrated control is equipped with an LED light for troubleshooting

Off -No power to control or board fault detected

On- Board fault detected,

Heartbeat1- Control powered – displayed during all modes of operation if no errors are detected

1 Reverse Line Voltage Polarity

2 Improper Earth Ground

3 Burner failed to light, or lost flame during heat demand

4 Low Flame Signal – check flame sensor

5 Watchguard – burner failed to light, exceeded maximum number of retries or recycles.

6 Not Used

7 Primary or Secondary Limit Open or Watchguard Mode  – Limit Switch Open longer than 3 minutes.

8 Rollout Switch Open

9 Pressure Switch failed to close or opened during heat demand

10 Watchguard – Pressure Switch opened 5 times during one heat demand

11 Pressure Switch stuck closed prior to activation of combustion air inducer

12 Flame Sensed without gas valve energized

13 Low Line Voltage

Notes:

Note 1

A ”Heartbeat” is indicated by a ”Slow Flash” – 1 sec on 1 sec off, repeating

Note 2

Error codes are indicated by a ”Rapid Flash” – the LED flashes X times at 1/2 sec on 1/2 sec off, remains off for 3 sec, then repeats

Note 3
Last 10 error codes are stored in memory including when power is shut off to the unit. – To recall, press and release button, most recent will be displayed first, LED off for 3 sec, then next error code is displayed, etc. To clear error codes, depress and hold button longer than 5 seconds.

Lennox AC Error Codes and Troubleshooting

INSTALLATION OPERATING & MAINTENANCE MANUAL:

Lennox Rooftop Service Manual

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...