Koppel Super Inverter AC Error Codes;
![Koppel Air Conditioner Error Codes](https://acerrorcode.com/wp-content/uploads/2019/05/Koppel-Air-Conditioner-Error-Codes.jpg)
Error Codes | Problem |
---|---|
E0 | Indoor unit EEPROM parameter error |
E1 | Indoor / outdoor units communication error |
E2 | Zero-crossing signal error |
E3 | Indoor fan speed has been out of control |
E4 | Open circuit or short circuit of indoor room temperature T1 |
E5 | Open circuit or short circuit of evaporator coil temperature T2 sensor |
EC | Refrigerant Leakage Detection |
F1 | Open circuit or short circuit of outdoor ambient T4 temperature sensor |
F2 | Open circuit or short circuit of condenser coil temperature T3 sensor |
F3 | Open circuit or short circuit of compressor discharge T5 temperature sensor |
F4 | Outdoor unit EEPROM parameter error |
F5 | Outdoor fan speed has been out of control |
P0 | IPM malfuntion of IGBT over-strong current protection |
P1 | Over voltage or over low voltage protection |
P2 | High temperature protection of compressor top diagnosis and solution |
P4 | Inverter compressor drive sensor |
![Indoor Unit Error Display - Timer Lamps -Display-Led Status E/F/P Error](https://acerrorcode.com/wp-content/uploads/2015/04/E0-E1-E2-E3-E4-E5-EC-F1-F2-F3-F4-F5-P0-P1-P2-P4.png)
EEPROM parameter error diagnosis and solution E0/F4:
Error Signals On The Display
In case of error, the display on the indoor unit shown the following error codes
Error Code: E 1
RUN lamp: flashes once
Description of the trouble: The fault of indoor temperature sensor
Error Code: E 2
RUN lamp: flashes twice
Description of the trouble: The fault of indoor pipe temperature sensor
Error Code: E 6
RUN lamp: flashes 6 times
Description of the trouble: Malfunction of indoor fan motor.
![Koppel Super Inverter AC Error Codes](https://acerrorcode.com/wp-content/uploads/2015/04/Koppel-Super-Inverter-AC-Error-Codes.jpg)
Koppel AC Troubleshooting
Malfunction: The appliance does not operate
Possible Causes:
- Power failure/plug pulled out
- Damaged indoor/outdoor unit fan motor
- Faulty compressor thermomagnetic circuit breaker
- Faulty protective device or fuses.
- Loose connections or plug pulled out
- It sometimes stops operating to protect the appliance.
- Voltage higher or lower than the voltage range
- Active TIMER-ON function
- Damaged electronic control board
Malfunction: Strange odour
Possible Causes: Air filter dirty
Malfunction: Noise of running water
Possible Causes: Back flow of liquid in the refrigerant circulation
Malfunction: A fine mist comes from the air outlet
Possible Causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes
Malfunction: A strange noise can be heard
Possible Causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Malfunction: Insufficient airflow, either hot or cold
Possible Causes:
- Inappropriate temperature setting..
- Air inlet or outlet of indoor or outdoor unit has been blocked.
- Air filter is blocked.
- Fan speed set at minimum.
- Other sources of heat in the room.
- No refrigerant
![Koppel Air Conditioner Remote Control](https://acerrorcode.com/wp-content/uploads/2015/04/koppel-ac-remote-control.jpg)
Malfunction: The appliance does not respond to commands
Possible Causes:
- Remote control is not near enough to indoor unit.
- Battery in Remote controller may have been exhausted..
- Obstacles between remote control and signal receiver in indoor unit.
Malfunction: The display is off
Possible Causes:
- Active LED function
- Power failure
The air conditioner does not work at all.
- Is the power plug inserted into the socket properly?
- Is the timer set for the “TIMER-ON” mode?
- Is the ambient temperature lower than 16°C?
- Is there a power failure or is the fuse blown?
There is no sufficient cooling
- Is the room temperature set properly?
- Is the air filter screen clean (not blocked)?
- Are the doors or windows opened?
- Is the room directly exposed to sunlight?
- Are there any heating sources inside the room?
- Are there many people inside the room?
![](https://acerrorcode.com/wp-content/uploads/2019/02/Koppel-Window-Type-AC-Remote-Control.jpg)
The following phenomena occurring during the operation do not mean faults of the machine. You may use the air conditioner with peace of mind.
Phenomena: The air conditioner cannot be started for operation after it is turned off.
Diagnosis: Start the operation after 3 minutes. This is to protect the air conditioner. The microchip protection device for 3 minutes’ delay performs its function. When the machine is powered for the first time. this function does not work.
Phenomena: Frog is blown out during the cooling operation.
Diagnosis: When the indoor temperature and humidity is high, such phenomena might occur. When the indoor temperature and humidity drops, the frog will disappear.
![](https://acerrorcode.com/wp-content/uploads/2019/02/Koppel-Window-Type-AC-Remote-Control-2.jpg)
Phenomena: There is odd smell of the delivered air.
Diagnosis: It might be the smell of cigarette smoke or other things inside the air conditioner.
Phenomena: There is “squeezing” sound.
Diagnosis: It might be caused by the cycling of the refrigerant inside the air conditioner.
Phenomena: There is “patting” sound.
Diagnosis: It might be caused by the heat expansion of contraction of the plastic parts.
Phenomena: There is moisture at the air outlet grids.
Diagnosis: If the air conditioner operates in high humidity for long time, moisture may be condensed at the grids and become water drops.
![](https://acerrorcode.com/wp-content/uploads/2019/02/Koppel-Window-Type-AC-Display-Panel.jpg)
1-Digital Displayer: in usual operation, ın fan mode, ıt indicates room temperature; ın cool or dry mode, ıt indicates setting temperature; ın timer operation, when pressing the timer button, it indicates timer time, if the time has not been be adjusted after 5 seconds, it indicates temprature again; lf room temp sensor failure, ıt indicates temperature at 25‘c (77°f).
2-Remote Controller Signal Receiver
3-Timer Button: if unit is running, press this button will enter switch-off mode; if unit is off (in standby mode), press this button will enter switch-on mode.
4-Speed Button: press this button to set air rate you want: high, med, low.
5-Mode Button: press this button,it advances the operation mode as follows: cool -dry-fan(heat for cooling and heating model)—auto
6-Tempitime Button: in usual, press this button to adjust setting temperature within a range of 16‘c(61°f) to 32’s (90“f).
7-Swing Button: pressing this button will adjust the air swinging direction or the air delivery in fixed direction.
![](https://acerrorcode.com/wp-content/uploads/2019/02/Koppel-Window-Type-AC-Troubleshooting.jpg)