Code Display | Malfunction Name |
---|---|
E1 | High pressure protection of system |
E2 | Antifreezing protection |
E3 | System block or refrigerant leakage |
E4 | High discharge temperature protection of compressor |
E5 | Overcurrent protection |
E6 | Communication Malfunction |
E8 | High temperature resistant protection |
EE | EEPROM malfunction |
EU | Limit/ decrease frequency due to high temperature of module |
C5 | Malfunction protection of jumper cap |
Fo | Gathering refrigerant |
F1 | Indoor ambient temperature sensor is open/short circuited |
F2 | Indoor evaporator temperature sensor is open/short circuited |
F3 | Outdoor ambient temperature sensor is open/short circuited |
F4 | Outdoor condenser temperature sensor is open/short circuited |
F5 | Outdoor discharge temperature sensor is open/short circuited |
F6 | Limit/ decrease frequency due to overload |
F8 | Decrease frequency due to overcurrent |
F9 | Decrease frequency due to high air discharge |
FH | Limit/ decrease frequency due to antifreezing |
PH | Voltage for DC bus-bar is too high |
PL | Voltage of DC bus-bar is too low |
P0 | Compressor Min frequence in test state |
P1 | Compressor rated frequence in test state |
P2 | Compressor maximum frequence in test state |
P3 | Compressor intermediate frequence in test state |
P5 | Overcurrent protection of phase current for compressor |
PU | Charging malfunction of capacitor |
P7 | Malfunction of module temperature sensor circuit |
P8 | Module high temperature protection |
H0 | Decrease frequency due to high temperature resistant during heating operation |
H2 | Static dedusting protection |
H3 | Overload protection for compressor |
H4 | System is abnormal |
H5 | IPM protection |
H5 | Module temperature is too high |
H6 | Internal motor (fan motor) do not operate |
H7 | Desynchronizing of compressor |
HC | PFC protection |
L3 | Outdoor DC fan motor malfunction |
L9 | Power protection |
LP | Indoor unit and outdoor unit doesn't match |
LC | Failure startup |
U1 | Malfunction of phase current detection circuit for compressor |
U3 | Malfunction of voltage dropping for DC bus-bar |
U5 | Malfunction of complete units current detection |
U7 | The four-way valve is abnormal |
U9 | Zerocrossing malfunction of outdoor unit |
U8 | Zero-crossing inspection circuit malfunction of the IDU fan motor |

Analysis or processing of some of the malfunction display:
- Compressor discharge protection
Possible causes: shortage of refrigerant; blockage of air filter; poor ventilation or air flow short pass for condenser; the system has noncondensing gas (such as air, water etc.); blockage of capillary assy (including filter); leakage inside four-way valve causes incorrect operation; malfunction of compressor; malfunction of protection relay; malfunction of discharge sensor; outdoor temperature too high. Processing method: refer to the malfunction analysis in the above section.
- Low voltage overcurrent protection
Possi ble cause: Sudden drop of supply voltage.
- Communication malfunction
Processing method: Check if communication signal cable is connected reliably.
- Sensor open or short circuit
Processing method: Check whether sensor is normal, connected with the corre sponding position on the controller and if damage of lead wire is found.
- Compressor over load protection
Possible causes: insufficient or too much refrigrant; blockage of capillary and increase of suction temp.; improper running of compressor, burning in or stuck of bearing, damage of discharge valve; malfunction of protector. Processing method: adjust refrigerant amount; replace the capillary; replace the compressor; use universal meter to check if the contactor of compress or is fine when it is not overheated, if not replace the protector.
- System malfunction
i.e.overload protection.When tube temperature(Check the temperature of outdoor heat exchanger when cooling and check the temperatur e of indoor heat exchanger when heating) is too high, protectionwill beactivated. Possi ble causes: Outdoor temperature is too high when cooling; insufficient outdoor air circulation; refrigerant flow malfunction. please refer to the malfunction analysis in the previous section for handling method .
- IPM module protection
Processing method:Once the module malfunction happens,if it persists for a long time and can not be selfcanceled, cut off the power and turn off the unit,and then re-energize the unit again after about 10 min.After repeating the procedure for sever times, if the malfunction still exists,replace the module.