Hyundai Air Conditioner Error Codes

 Protection and Failure Display

  • When protection display is available, controller will show error code, digital LED shows error code and setting temperature by turns.
  • If there is more than one failure, it will show at first that in front of the error list.
  • Protection display function can be selected in hardware, and the default don’t display;
  • To insure of in and out communist is credibility, the failures relate to outdoor unit will remain failure state for 2 minutes max after recovered.
  • In all failures, only sensor failures don’t have to repower to cancel.
Hyundai Air Conditioner Error Codes
Hyundai Air Conditioner Error Codes

Error List

Error CodeLed CodeFailure Type
E0RUN, TIMER–both winkingIn and out communication failure
ECRUN, TIMER–both winkingOutdoor communication failure
E1RUN-1 time/8sOutdoor sensor
E2RUN-2 times /8sIndoor coil temperature sensor
E3RUN-3 times /8sOutdoor coil temperature sensor
E4RUN-4 times /8sSystem abnormity
E5RUN-5 times /8sType mismatch
E6RUN-6 times /8sIndoor fan motor
E7RUN-7 times /8sOutdoor temperature sensor
E8RUN-8 times /8sDischarge temperature sensor
E9RUN-9 times /8sInvert module abnormity
EFRUN-10 times /8sOutdoor fan motor (DC)
EARUN-11 times /8sCurrent sensor
EERUN-12 times /8sEEPROM failure
EPRUN-13 times /8sTop of compressor temperature switch
EURUN-14 times /8sVoltage sensor
Protection Display Code List
P1RUN-winking,TIMER-1 time/8shigher or lower voltage
P2RUN- winking,TIMER-2 times /8sOver current
P4RUN- winking,TIMER-4 times /8sDischarge temperature
P5RUN-light,TIMER-5 times /8sOver cooling in cooling mode
P6RUN- light,TIMER-6 times /8sOver heating in cooling mode
P7RUN- light,TIMER-7 times /8sOver heating in heating mode
P8RUN- light,TIMER-8 times /8sOutdoor temperature too high or low
P9RUN- winking,TIMER-9 times/8sDrive protection (Overload)
P0RUN- winking,TIMER-10 times/8sModule self protection
Hyundai Air Conditioner Remote Control
Hyundai Air Conditioner Remote Control

Outdoor Failure Display

There is a LED on outdoor power board, when compressor is running; it is normally light; when no feedback of signal to power board from compressor, it will wink by lighting 1s and going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go out 3s for a cycle to indicate failures. The failure list is the follow:

Hyundai Air Conditioner Outdoor Failure Display
Hyundai Air Conditioner Outdoor Failure Display
Wink timeFailure
1IPM protection
2higher or lower voltage
3Over current
4Discharge temperature too high
5Outdoor coil temperature too high
6Drive abnormity
7Communication abnormity with indoor unit
8Compressor over heat(switch on top of compressor)
9Outdoor air temperature sensor failure
10Outdoor coil temperature sensor failure
11Outdoor discharge pipe temperature sensor failure
12Voltage sensor failure
13Current sensor failure
14IPM abnormity
15Outdoor communication abnormity
16DC fan motor no feedback
17defrosting

Hyundai Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive load on the board. Problem:  NO

York VRF Error Codes

  Malfunction and Protection Code Table. The display board in digital scroll system is just to display running conditions and  malfunction information. The manual button is just to check the address code and power code  of indoor units. York VRF Error Codes Malfunction and Protection Code Table: Error Codes Contents E0 Phase sequence or lack of phase E1 Communication malfunction E2 T1 sensor malfunction E3 T2A sensor malfunction E4 T2B sensor malfunction E5 T3 sensor malfunction E6 Over-zero checking malfunction E7 EEPROM malfunction E8 Fan motor checking out of control E9 Communication malfunction between PCB and Display board EF Other malfunction EE Water level checking malfunction ED Outdoor protection EC Clear malfunction EB Inverter Module Protection EA Compressor Over-current (4 times) P0 Evaporator Temp. Protection P1 Anti-cooling or Defrost Protection P2 Condenser High Temp. Protection P3 Compressor Temp. Protection P4 Discharge Pipe Temp. Protection P5 Discharge High-pressure