Garrison Air Conditioner Error Codes

Error CodesMeaning
E5It is water full in the unit, you should drain the water
E41-Pull out the rubber plug to drain water. 2-If it is often in this state, please contact qualified service technician.
ASRoom temperature sensor error-Unplug the unit and plug it back in.
HSElectric heating sensor error-Unplug the unit and plug it back in.
  1. Portable AC
  2. Window/Wall-Type AC

1- Portable AC Error Codes:

Garrison Portable AC Error Codes
Garrison Portable AC Error Codes
  • If the unit displays error code E5, it is water full in the unit, you should drain the water, see “Draining the air conditioner”. After draining, you can operate and use the unit again.
  • Does not run and water full indicator E4; 1-Pull out the rubber plug to drain water. 2-If it is often in this state, please contact qualified service technician.

2- Window/Wall-Type AC Error Codes:

Garrison Window-Wall Type AC Error Codes
Garrison Window-Wall Type AC Error Codes
  • AS Error: Room temperature sensor error-Unplug the unit and plug it back in.
  • HS Error: Electric heating sensor error-Unplug the unit and plug it back in.

Note: If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.

Troubleshooting

Problem: Air conditioner does not start

Solution:

  • Wall plug disconnected. Push plug firmly into wall outlet.
  • House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
  • Plug on current device tripped. Press the RESET button.
  • Power is OFF. Turn power ON

Problem: Air from unit does not feel cold enough

Solution:

  • Room temperature below 62 F (17 C ). Cooling may not occur until room temperature rises above 62 F (17 C).
  • Temperature sensing behind air filter element touching cold coil. Keep it from the cold coil.
  • Set to a Lower temperature.
  • Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode.

Problem: Air conditioner cooling, but room is too warm- ice forming on cooling coil behind decorative front.

Solution:

  • Outdoor temperature below 64 F (18 C). To defrost the coil, set FAN ONLY mode.
  • Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
  • Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, set temperature to a Higher setting.

Problem: Air conditioner cooling, but room is too warm- no ice forming on cooling coil behind decorative front.

Solution:

  • Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section.
  • Temperature is set too High, set temperature to a Lower setting.
  • Air directional louvers positioned improperly. Position louvers for better air distribution.
  • Front of units is blocked by drapes, blinds, furniture, etc. – restricts air distribution. Clear blockage in front of unit.
  • Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers.
  • Unit recently turned on in hot room. Allow additional time to remove Stored heat from walls, ceiling, floor and furniture.

Problem: Air conditioner turns on and off rapidly

Solution:

  • Dirty air filter- air restricted. Clean air filter.
  • Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past cooling coils more frequently.

Problem: Noise when unit is cooling

Solution:

  • Air movement sound. This is normal . If too loud, set to a slower FAN setting
  • Window vibration – poor installation. Refer to installation instructions or check with installer.

Problem: Water dripping INSIDE when unit is cooling.

Solution: Improper installation. Tilt air conditioner slightly to the outside to allow water drainage.
Refer to installation instructions – check with installer.

Problem: Water dripping OUTSIDE when unit is cooling.

Solution: Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.

Problem: Remote Sensing Deactivating Prematurely

Solution:

  • Remote control not located within range. Place remote control within 20 feet & 180 , radius of the front of the unit.
  • Remote control signal obstructed. Remove obstruction.

Problem: Room too cold

Solution: Set temperature too low. Increase set temperature.

Garrison Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...