Skip to main content

Everstar AC Error Codes and Troubleshooting

 Everstar Portable Air Conditioner Error Codes;

Everstar AC Error Codes and Troubleshooting
Everstar AC Error Codes and Troubleshooting
Error CodesProblem-Solution
P1The LCD window will shows "P1" and the Water Full indicator will flash every 0.5 seconds.
P2Compressor does not work and the digital display area shows “ P2 ". The bottom tray is full
E1The cooting indicator light flashes at 1H: and the digital display area shows “E1 ". The room temperature Sensor is off or shon-circuit.
E2The FAN indicator light flashes at 1H: and the digital display area shows “ E2 ". The Evaporator Temperature Sensor is off or short-circuit.
E3The Dehumidifying indicator light flashes at 1H: and the digital display area shows ''E3''. The Condenser Temperature Sensor is off or short-circuit.

Troubleshooting

Troubles: Unit does not Start when Pressing onloff Button

Possible Causes:

  1. Wateriull indicator blinks, water tank is full.
  2. Room temperature is higher than the set temperature.
  3. Room temperature is lower than the set temperature.

Suggest Remedies:

  1. Dump the water in the water tank.
  2. Reset the temperature.
  3. Reset the temperature.

Troubles: Not cool enough

Possible Causes:

  1. The windows or doors in the room are not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. Air filter is blocked by dust.

Suggest Remedies:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources it possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Troubles: Noisy or vibration

Possible Causes: The ground is not level or not flat enough.

Suggest Remedies: Place the unit on a flat. level ground if possible.

Troubles: Gurgling sound

Possible Causes: The sound comes from the flowing of the refrigerant inside the air conditioner.

Suggest Remedies: It is normal.

How to Fix P1 Error?

How to Fix P1 Error
How to Fix P1 Error

This unit is equipped with a fail-safe switch mechanism which prevents the unit from condensing water in the event the water tank is accidentally displaced, and / or FULL with water. If this situation occurs, the LED window shows “P1” and the WATER FULL indicator light will flash red continuously until the water tank is correctly positioned and/or emptied. Condensed water will be accumulated in the water tank. When the tank is full, the LED window will show “P1” and the Water Full indicator light start flashing. At this time the air cooling process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully remove the water tank from the cabinet and dispose of the water. Replace the water tank back to it’s original position (in cabinet) and the air cooling process will automatically resume. It may take 3-5 minutes for the compressor to re-start. This is normal.

Everstar Portable Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...