Everstar AC Error Codes and Troubleshooting

 Everstar Portable Air Conditioner Error Codes;

Everstar AC Error Codes and Troubleshooting
Everstar AC Error Codes and Troubleshooting
Error CodesProblem-Solution
P1The LCD window will shows "P1" and the Water Full indicator will flash every 0.5 seconds.
P2Compressor does not work and the digital display area shows “ P2 ". The bottom tray is full
E1The cooting indicator light flashes at 1H: and the digital display area shows “E1 ". The room temperature Sensor is off or shon-circuit.
E2The FAN indicator light flashes at 1H: and the digital display area shows “ E2 ". The Evaporator Temperature Sensor is off or short-circuit.
E3The Dehumidifying indicator light flashes at 1H: and the digital display area shows ''E3''. The Condenser Temperature Sensor is off or short-circuit.

Troubleshooting

Troubles: Unit does not Start when Pressing onloff Button

Possible Causes:

  1. Wateriull indicator blinks, water tank is full.
  2. Room temperature is higher than the set temperature.
  3. Room temperature is lower than the set temperature.

Suggest Remedies:

  1. Dump the water in the water tank.
  2. Reset the temperature.
  3. Reset the temperature.

Troubles: Not cool enough

Possible Causes:

  1. The windows or doors in the room are not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. Air filter is blocked by dust.

Suggest Remedies:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources it possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Troubles: Noisy or vibration

Possible Causes: The ground is not level or not flat enough.

Suggest Remedies: Place the unit on a flat. level ground if possible.

Troubles: Gurgling sound

Possible Causes: The sound comes from the flowing of the refrigerant inside the air conditioner.

Suggest Remedies: It is normal.

How to Fix P1 Error?

How to Fix P1 Error
How to Fix P1 Error

This unit is equipped with a fail-safe switch mechanism which prevents the unit from condensing water in the event the water tank is accidentally displaced, and / or FULL with water. If this situation occurs, the LED window shows “P1” and the WATER FULL indicator light will flash red continuously until the water tank is correctly positioned and/or emptied. Condensed water will be accumulated in the water tank. When the tank is full, the LED window will show “P1” and the Water Full indicator light start flashing. At this time the air cooling process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully remove the water tank from the cabinet and dispose of the water. Replace the water tank back to it’s original position (in cabinet) and the air cooling process will automatically resume. It may take 3-5 minutes for the compressor to re-start. This is normal.

Everstar Portable Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive load on the board. Problem:  NO

York VRF Error Codes

  Malfunction and Protection Code Table. The display board in digital scroll system is just to display running conditions and  malfunction information. The manual button is just to check the address code and power code  of indoor units. York VRF Error Codes Malfunction and Protection Code Table: Error Codes Contents E0 Phase sequence or lack of phase E1 Communication malfunction E2 T1 sensor malfunction E3 T2A sensor malfunction E4 T2B sensor malfunction E5 T3 sensor malfunction E6 Over-zero checking malfunction E7 EEPROM malfunction E8 Fan motor checking out of control E9 Communication malfunction between PCB and Display board EF Other malfunction EE Water level checking malfunction ED Outdoor protection EC Clear malfunction EB Inverter Module Protection EA Compressor Over-current (4 times) P0 Evaporator Temp. Protection P1 Anti-cooling or Defrost Protection P2 Condenser High Temp. Protection P3 Compressor Temp. Protection P4 Discharge Pipe Temp. Protection P5 Discharge High-pressure