Electriq AC Error Codes and Troubleshooting

 Wall Mounted Inverter Multi Split Air Conditioner with Heat Pump. Model: eiQ-9K9KC18KWMINV

ElectriQ air conditioners have an advanced self-diagnosis system allowing them to display the service information.

Protection and Fault Codes for Indoor Unit Board;

Error CodesMeaning
F0Abnormal zero passage of PG motor
F1Abnormal communication between indoor unit and outdoor unit
F2Open circuit or short circuit of Tr sensor
F3Open circuit or short circuit of Tp sensor
F4Malfunction of indoor fan
E9Open circuit or short circuit of PM 2.5 sensor
F5Malfunction of outdoor module
F6Open circuit or short circuit of outdoor temp sensor
F7Open circuit or short circuit of outdoor coil temp sensor
F8Open circuit or short circuit of compressorsuction temp sensor
F9Open circuit or short circuit of compressorextraction temp sensor
FAMalfunction of current and potential transformer
FCMalfunction of compressor drive
FDPower phase sequence fault or open phase fault
FEOpen circuit or short circuit of air return sensor
FHMalfunction of outdoor DC fan
FbMulti-split mode conflict protection

Outdoor Board Fault Codes

Electriq AC Error Codes
Electriq AC Error Codes
Error CodesMeaning
EEAEEPROM fault
EEBEEPROM fault
E0Fault of communication between coordination board and driver board
ECFault of communication between variable frequency module and outdoor unit
E0A1# indoor communication fault
E0B2# indoor communication fault
E0C3# indoor communication fault
E0D4# indoor communication fault
E0E5# indoor communication fault
E10Weak current communication fault
E9Variable frequency drive/module fault
EPCompressor shell roof switch fault
EUVoltage sensor fault
E3T3 temperature sensor fault
E7T4 temperature sensor fault
E8Exhaust temperature sensor fault
EHAir return temperature sensor fault
EtA1#T2B1 temperature sensor fault
EtB2#T2B2 temperature sensor fault
EtC3#T2B3 temperature sensor fault
EtD4#T2B4 temperature sensor fault
EtE5#T2B5 temperature sensor fault
P0IPM module protection
P9Compressor drive fault protection
P9HP dial setting fault
P1Low-voltage protection
P2Compressor current protection
P4Exhaust gas high temperature protection
H1High-voltage switch protection
H2Low-voltage switch protection
P6Refrigerator T3 overheat protection

Troubleshooting

Electriq AC Remote Control
Electriq AC Remote Control

Trouble: The unit does not work

Reason:

  1. No power supply
  2. Water-full indicator illuminated
  3. Timer function is active
  4. Room temperature too low or too high

Solution:

  1. Power-on and turn on the unit
  2. Drain the internal water tank
  3. Cancel Timer function
  4. Use only in ambient temperatures between 7-35℃

Trouble: The unit does not seem to perform

Reason:

  1. In direct sunlight
  2. Windows or doors open. Large amount of people or a heat source in the room
  3. Filter is very dirty
  4. Air inlet or air outlet is blocked
  5. Room temperature is lower than setting temperature

Solution:

  1. Draw the curtains, UV affects RC
  2. Close windows and turn on another air conditioner
  3. Clean or change the air filter
  4. Clear out debris
  5. Change the setting temperature

Trouble: The unit loud

Reason: The unit is not put on flat surface

Solution: Put the unit on flat and hard surface

Trouble: Compressor does not work

Reason: Overheating protection is active

Solution:

  1. Check venting.
  2. Restart the unit after 5 minutes when compressor has cooled

Trouble: Remote control doesn’t work

Reason:

  1. Operating distance is too far.
  2. Control panel has not received the signal from remote control.
  3. The batteries are flat

Solution:

  1. Move remote control closer to the unit and make sure it aims at the air-outlet grille
  2. Replace the batteries

Electriq AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...