Daihatsu Air Conditioner Error Codes

 

Daihatsu Air Conditioner Error Codes
Daihatsu Air Conditioner Error Codes

Daihatsu Inverter Air Conditioner Error Codes; When air conditioner status is abnormal, temperature indictor on indoor unit will blink to display corresponding error code. Please refer to below list for identific ation of error code.

Digital LED CodeFailure Type-LED Code-Function Indicator (flash)
E0Indoor and outdoor communication failure. RUN, TIMER – both winking.
ECOutdoor communication failure. RUN TIMER – both winking.
E1Indoor room temperature sensor (IRT). RUN-1 time/8s.
E2Indoor coil temperature sensor (IPT). RUN-2 times /8s.
E3Outdoor coil temperature sensor (OPT). RUN-3 times /8s.
E4System abnormity. RUN-4 times /8s.
E5Model configuration wrong. RUN-5 times /8s.
E6Indoor fan motor fault. RUN-6 times /8s.
E7Outdoor temperature sensor. RUN-7 times /8s.
E8Exhaust temp. sensor. RUN-8 times /8s.
E9IPM drive and module fault. RUN-9 times /8s.
EFOutdoor fan motor fault (DC motor). RUN-10 times /8s.
EACurrent sensor fault. RUN-11 times /8s.
EEIndoor unit EEPROM fault. RUN-12 times /8s.
EPTemp. switch fault ( on top of the compressor). RUN-13 times /8s.
EUVoltage sensor fault. RUN-14 times /8s.
P1Overvoltage /lower voltage protection. RUN: Blink; TIMER: 1 blink /8 sec.
P2Overcurrent protection. RUN: Blink; TIMER: 2 blink /8 sec.
P4Exhaust over temperature protection. RUN: Blink; TIMER: 4 blink /8 sec.
P5Too cool protection in cooling mode. RUN: Bright; TIMER: 5 blink /8 sec.
P6Overheat protection in cooling mode. RUN: Bright; TIMER: 6 blink /8 sec.
P7Overheat protection in heating mode. RUN: Bright; TIMER: 7 blink /8 sec.
P8Outdoor over temperature / lower temperature protection. RUN: Bright; TIMER: 8 blink /8 sec.
P9Drive protection (software control ). RUN: Blink; TIMER: 9 blink /8 sec.
P0Module protection (hardware control). RUN: Blink; TIMER: 10 blink /8 sec.
C5Connector jumper malfunction. Check if the connector jumper contacts the properly. If replace the PCB, please take off the old for the new PCB.
H6PC motor (indoor fan) can’t run. Feedback terminal of PG motor hasn’t been connected firmly. The control end of PG motor hasn’t been connected firmly
U8Malfunction of zero cross detection circuit for PG motor (indoor fan). Control panel has been damaged.
daihatsu air conditioner remote controller
Daihatsu Air Conditioner Remote Controller

Outdoor failure display

There is a LED on outdoor power board, it blinks 1s ON and 1s OFF while compressor standby and it always light (ON) while compressor running; If there is failure happened on ODU, The indicator (LED) alerts the fault in a cycle as such that it is bright for 0.5 seconds, dark for 0.5 seconds, blinks “n” times and then dark for 3 seconds. For details as table below:

Display on outdoor power source board:


blink time (n)Failure
1IPM protection
2Over voltage /lower voltage
3Overcurrent
4Exhaust over temperature protection
5Outdoor coil over temperature protection
6Drive fault and protection (V1ˈVP1)
7Communication fault with indoor unit
8Compressor overheat fault (compressor top switch)
9Short-circuit / open-circuit fault of outdoor temperature sensor
10Short circuit / open-circuit fault of outdoor heat exchanger temperature sensor
11Short-circuit / open-circuit fault of exhaust temperature sensor
12Voltage sensor fault
13Current sensor fault
14IPM fault
15Communication fault between power source board and IPM
16No feedback from DC fan motor(outdoor unit)
17Defrost state

Daihatsu Air Conditioner Troubleshooting

Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals.

TroubleSolution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.Whether it’s interfered severely (such as static electricity,stable voltage)? Pull out the plug. Reinsert the plug after about 3 min, and then turn on the unit again.
Whether remote controller is within the signal receiving range? Signal receiving range is 8m.
Whether there are obstacles? Remove obstacles.
Whether remote controller is pointing at the receiving window? Select proper angle and point the remote controller at the receiving window on indoor unit.
Is sensitivity of remote controller low; fuzzy display and no display? Check the batteries. If the power of batteries is too low, please replace them.
No display when operating remote controller? Check whether remote controller appears to be damaged. If yes, replace it.
Fluorescent lamp in room? Take the remote controller close to indoor unit. Turn off the fluoresent lamp and then try it again.
No air emitted from indoor unitAir inlet or air outlet of indoor unit is blocked? Eliminate obstacles.
Under heating mode, indoor temperature is reached to set temperature? After reaching to set temperature, indoor unit will stop blowing out air.
Heating mode is turned on just now? In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
Air conditioner can’t operatePower failure? Wait until power recovery.
Is plug loose? Reinsert the plug.
Air switch trips off or fuse is burnt out? Ask professional to replace air switch or fuse.
Wiring has malfunction? Ask professional to replace it.
Unit has restarted immediately after stopping operation? Wait for 3 min, and then turn on the unit again.
Whether the function setting for remote controller is correct? Reset the function.
Mist is emitted from indoor unit’s air outletIndoor temperature and humidity is high? Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
Odours are emittedWhether there’s odour source, such as furniture and cigarette, etc. Eliminate the odour source. Clean the filter.
Air conditioner operates normally suddenlyWhether there’s interference, such as thunder, wireless devices, etc. Disconnect power, put back power, and then turn on the unit again.
Outdoor unit has vaporHeating mode is turned on? During defrosting under heating mode, it may generate vapor, which is a normal phenomenon.
“Water flowing” noiseAir conditioner is turned on or turned off just now? The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.
Cracking noiseAir conditioner is turned on or turned off just now? This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.

Introduction for buttons on remote controller

Introduction for buttons on remote controller
Introduction for buttons on remote controller

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...