Skip to main content

Daewoo AC Error Codes and Troubleshooting

 The following table shows the fault protections.

Daewoo Air Conditioner Error Codes and Troubleshooting
Daewoo Air Conditioner Error Codes and Troubleshooting
Error CodesSolution
Indoor unitLED display function
E0EEPROM error
E1Indoor and outdoor communication error
E2Zero-crossing examination error
E3Fan speed beyond control
E5Outdoor units temp. sensor or connector of temp. sensor is defective
E6Indoor units temp. sensor or connector of temp. sensor is defective
P0Inverter module protection
P1Outdoor voltage protection
P2Compressor top protection against temperature
P3Compressor current protection
P5Outdoor low temp. protection
Outdoor unitLED display function
E0EEPROM error
E1No 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E2No 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E3No 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E4Outdoor temp. sensor or connector of temp. sensor is defective
E5Compressor voltage protection
E6No 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E7Indoor and outdoor communication error
P0Compressor top protection against temperature
P1High pressure protection
P2Low pressure protection
P3Compressor current protection
P4Inverter module protection
P5Outdoor low temp. protection
P6Condenser high-temperature protection

Troubleshooting

Before requesting service, please refer to the chart below for possible solutions:

Symptoms: No power

Possible Cause:

  1. Power failure.
  2. Line voltage too low.
  3. Unit is unplugged or not completely plugged in.
  4. Unit is off.
  5. Batteries in remote are weak or dead.
  6. EMERGENCY/REMOTE switch is not set to REMOTE.

Possible Solutions:

  1. Restore the power.
  2. Contact electrician to install new outlet.
  3. Insert plug all the way.
  4. Turn unit on.
  5. Replace remote’s batteries.
  6. Slide EMERGENCY/REMOTE to REMOTE.

Symptoms: The compressor does not turn on. (no cool air)

Possible Cause:

  1. When the unit is first plugged in and turned on, the compressor will delay turn on for 3 minutes.
  2. If the unit is turned off and then immediately back on, the compressor will delay for 3 minutes.
  3. The air filter(s) is dirty or clogged.
  4. Unit is located near a heat source (heater, stove, etc.)
  5. A door or window is open.
  6. There is an obstacle in front of intake or indoor unit.
  7. Thermostat is set too high.

Possible Solutions:

  1. Wait 3 minutes for the unit to operate.
  2. Wait 3 minutes for the unit to operate.
  3. Clean or replace filter(s).
  4. When locating unit for the first time,make sure it is in a desirable location.
  5. Shut door or window.
  6. Remove obstacle.
  7. Set thermostat lower.

Symptoms: Strange sounds occur

Possible Cause: During operation, especially after turning it on or off, refrigerant flows inside the unit.

Possible Solutions: This is normal.

Symptoms: Strange smells occur.

Possible Cause: The fan is bringing out the smells of the carpet, walls, etc.

Possible Solutions: The smell should go away shortly.

Symptoms: No remote operation.

Possible Cause:

  1. Batteries are weak, dead or inserted improperly.
  2. Remote is out of range.
  3. Remote not aimed at sensor.
  4. There is an obstruction between unit and remote.

Possible Solutions:

  1. Replace batteries.
  2. Move closer to unit.
  3. Aim remote at sensor.
  4. Remove obstruction.

Self-Diagnostic Function

Error CODE- Display- Check point
Error CODE- Display- Check point
Failure phenomenon- Operation lamp -Timer lamp -Fan lamp
Failure phenomenon- Operation lamp -Timer lamp -Fan lamp

Indoor fan does not operate at all (E6).

How to fix E6
How to fix E6

Product does not operate at all.

Product does not operate at all
Product does not operate at all

Daewoo Air Conditioner Remote Control

Daewoo Air Conditioner Remote Control
Daewoo Air Conditioner Remote Control

 

Daewoo Air Conditioner Service Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...