Blue Star Ductable AC, Window AC, Inverter AC error codes list;

Error Codes | Problem |
---|---|
E0 | IDU EEPROM error |
E1 | ODU coil medium-high error |
E2 | IDU coil frozen protection |
E4 | Discharge temperature high error |
E5 | AC input over current protection |
E6 | Communication error |
E8 | Zero crossing error |
EE | ODU EEPROM error |
EC | Refrigerant leak detection |
F1 | Indoor room temperature sensor error |
F2 | IDU coil temperature sensor error |
F3 | Ambient temperature sensor error |
F4 | ODU coil temperature sensor error |
F5 | ODU discharge temperature sensor error |
P3 | Drive phase current over load fault |
P4 | DC bus bar high voltage and low voltage protection |
P7 | IPM error |
P5 | Compressor phase current protection |
P8 | IPM over high temperature protection |
PH | AC over voltage and under voltage protection |
L1 | Drive phase voltage over load protection |
L2 | Drive phase voltage over low protection |
L3 | Outdoor DC fan fault |
L4 | Phase current sampling abnormal |
LC | Compressor out of step fault |
LC | Compressor startup failure |
H6 | IDU fan motor error |
Troubleshooting
Symptoms: Unit does not start
Possible Causes: MCB has tripped
Suggested Remedy: Reset MCB
Symptoms: Fuse has burnt
Possible Causes:
- Input voltage to the stabiliser is below acceptable range
- Replace fuse wire
Suggested Remedy:
- If the input voltage to the stabiliser is below the acceptable range, the airconditioner will not turn on
Symptoms: Unit does not cool even after the normal time delay of approx. 2 minutes
Possible Causes:
- Compressor is off (not in Auto or Cool Mode)
- The airflow paths of either or both the indoor & outdoor units are not free
- The air-filter is not clean
Suggested Remedy:
- Use the remote to turn the compressor on
- Remove all obstructions to make the airflow paths free
- Clean the air-filter
NOTE: If the unit still does not work, or if any other types of symptoms are encountered, shut off the mains (switch fuse unit) and call the service engineer/technician.