Black and Decker Portable AC Error Codes and Troubleshooting

 The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance display.

Black and Decker Portable AC Error Codes and Troubleshooting
Black and Decker Portable AC Error Codes and Troubleshooting
Error CodesWhat should I do?
LEIf you displayed LE, Low Temperature (frost prevention) The appliance is fitted with a frost protection device to avoid excessive formation of ice. The appliance start up again automatically when the defrosting process is completed.
PFIf you displayed PF, Probe Failure (sensor damaged) If this is displayed, contact your local authorised service centre.
FEIf you displayed FE, Full Tank (safety tank full) Empty the internal safety tank, following the instructions in the ''End of season operations'' paragraph.
Black and Decker Portable AC Remote Control
Black and Decker Portable AC Remote Control

Troubleshooting

Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact W Appliance Co. customer service center or the nearest authorized service center. Customers must never troubleshoot internal components.

Trouble: Unit does not start when pressing ON/OFF button

Possible Cause:

  1. FT appears in the display window
  2. Room temperature is lower than set temperature (cooling mode)

Possible Remedy:

  1. Drain the water in the bottom tray
  2. Reset the temperature
Black and Decker Portable AC Control Panel
Black and Decker Portable AC Control Panel

Trouble: Not cool enough

Possible Cause:

  1. The windows or doors in the room are not closed
  2. There are heat sources inside the room
  3. Exhaust air duct is not connected or blocked
  4. Temperature setting is too high
  5. Air filter is blocked by dust
  6. The unit will take approx 3 minutes of operation before cooling/heating occurs.

Possible Remedy:

  1. Make sure all the windows and doors are closed
  2. Remove the heat sources if possible
  3. Connect the duct and make sure it can function properly
  4. Decrease the set temperature
  5. Clean the air filter
  6. A mircoprocessor control delays the compressor from operating until 3 mins have passed.

Trouble: Noisy or vibration

Possible Cause: The surface is not level or not flat enough

Possible Remedy: Place the unit on a flat, level surface if possible

Trouble: Gurgling sound

Possible Cause: The sound comes from the flowing of the refrigerant inside the air-conditioner

Possible Remedy: It is normal

Trouble: Unit stops operating

Possible Cause: LT appears in display window

Possible Remedy: Unit is in defrost mode and will restart automatically once excess frost has been removed.

Black and Decker Portable AC Troubleshooting
Black and Decker Portable AC Troubleshooting

Water Drainage Method

This air conditioner is equipped with the very latest MIST technology which means the water tank nearly never fills, hence water drainage will generally only be required at the end of the season (see START-END OF SEASON OPERATIONS in page 19. However the MIST technology does not operate when the unit is in HEAT mode. Thus the tank may still require emptying in HEAT mode.

NOTE: As a safety measure to positively prevent water spillage the air conditioner is equipped with a fail safe device if the water tank fills. The unit will completely stop, the control panel displays ft (FULL TANK) as mentioned on SELF DIAGNOSIS in page 17. The compressor and fan will not restart until the tank has been drained.

Cleaning The Filters

To keep your air conditioner working efficiently, you should clean the filters every week of operation. The evaporator filter can be removed as shown in Fig. 12.

Black and Decker Portable AC - Cleaning The Filters
Black and Decker Portable AC – Cleaning The Filters

The condenser filter is two pieces.

  • STEP 1: Take out one filter as shown in Fig. 13.
  • STEP 2: Take out other filter as shown in Fig. 14 and Fig. 15.

Use a vacuum cleaner to remove dust accumulations from the filters. If it is very dirty, immerse in warm water and rinse a number of times. The water should be luke warm. After washing, leave the filters to dry then re-insert.

Black and Decker Portable AC Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive load on the board. Problem:  NO

York VRF Error Codes

  Malfunction and Protection Code Table. The display board in digital scroll system is just to display running conditions and  malfunction information. The manual button is just to check the address code and power code  of indoor units. York VRF Error Codes Malfunction and Protection Code Table: Error Codes Contents E0 Phase sequence or lack of phase E1 Communication malfunction E2 T1 sensor malfunction E3 T2A sensor malfunction E4 T2B sensor malfunction E5 T3 sensor malfunction E6 Over-zero checking malfunction E7 EEPROM malfunction E8 Fan motor checking out of control E9 Communication malfunction between PCB and Display board EF Other malfunction EE Water level checking malfunction ED Outdoor protection EC Clear malfunction EB Inverter Module Protection EA Compressor Over-current (4 times) P0 Evaporator Temp. Protection P1 Anti-cooling or Defrost Protection P2 Condenser High Temp. Protection P3 Compressor Temp. Protection P4 Discharge Pipe Temp. Protection P5 Discharge High-pressure