Westinghouse Air Conditioner Error Codes

 Please read all of the instructions before using the air conditioner and keep this manual for future reference. The air conditioner you purchased has R410a gas  refrigerant a environmental friendly gas which does  not damage the ozone layer.

Westinghouse Air Conditioner Error Codes
Westinghouse Air Conditioner Error Codes

Error signals on the display:

In case of error, the display on the indoor unit shown the following error codes:

Error CodesDescription of the trouble
E0Indoor unit EEPROM parameter error.
E1Indoor / outdoor units communication error.
E2Zero-crossing signal detection error.
E3Indoor fan speed has been out of control.
E4Open circuit or short circuit of indoor room temperature T1 sensor.
E5Open circuit or short circuit of evaporator coil temperature T2 sensor
ECRefrigerant Leakage Detection
F1Open circuit or short circuit of outdoor ambient T4 temperature sensor
F2Open circuit or short circuit of condenser coil temperature T3 sensor
F3Open circuit or short circuit of compressor discharge T5 temperature sensor
F4Outdoor unit EEPROM parameter error
P0IPM malfunction or IGBT over-strong current protection
P1Over voltage or over low voltage protection
P2High temperature protection of compressor top diagnosis and solution
P4Inverter compressor drive error
Westinghouse Air Conditioner Error Codes; E1-E2-E6
Westinghouse Air Conditioner Error Codes; E1-E2-E6

Westinghouse Air Conditioner Troubleshooting

Malfunction: The appliance does not operate

Possible causes:

  • Power failure/plug pulled out
  • Damaged indoor/outdoor unit fan motor
  • Faulty compressor thermomagnetic circuit breaker
  • Faulty protective device or fuses.
  • Loose connections or plug pulled out
  • It sometimes stops operating to protect the appliance.
  • Voltage higher or lower than the voltage range
  • Active TIMER-ON function
  • Damaged electronic control board
Westinghouse Air Conditioner Remote Control Display
Westinghouse Air Conditioner Remote Control Display

Malfunction: Strange odour

Possible causes: Dirty air filter

Malfunction: Noise of running water

Possible causes: Back flow of liquid in the refrigerant circulation

Malfunction: A fine mist comes from the air outlet

Possible causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes.

Malfunction: A strange noise can be heard

Possible causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.

Westinghouse Air Conditioner Indoor unit display
Westinghouse Air Conditioner Indoor unit display

Malfunction: Insufficient airflow

Possible causes:

  • Unsuitable temperature setting.
  • Obstructed air conditioner intakes and outlets.
  • Dirty air filter.
  • Fan speed set at minimum.
  • Other sources of heat in the room.
  • No refrigerant.

Malfunction: The appliance does not respond to commands

Possible causes:

  • Remote control is not near enough to indoor unit.
  • The batteries of remote control nearly has no power.
  • Obstacles between remote control and signal receiver in indoor unit.

Malfunction: The display is off

Possible causes:

  • Active LIGHT function
  • Power failure

Malfunction: The display is off

Possible causes:

  • Active LIGHT function
  • Power failure

Malfunction: Switch off the air conditioner immediately and cut off the power supply in the event of:

Possible causes:

  • Strange noises during operation.
  • Faulty electronic control board
  • Faulty fuses or switches.
  • Spraying water or objects inside the appliance.
  • Overheated cables or plugs.
  • Very strong smells coming from the appliance.
Westinghouse Air Conditioner Parts
Westinghouse Air Conditioner Parts

SPLIT TYPE ROOM AIR CONDITIONER MANUAL PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

Innovair Air Conditioner Error Codes

 innovair  prestige  inverter mini split system: Innovair Air Conditioner Error Codes Error Codes Problem E2 Anti-freezing protection E3 Block or Low pressure of refrigerant system E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor unit and outdoor unit E8 Anti-high temperature protection H4 Anti-high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection LP Indoor unit and outdoor unit doesn't match L3 Outdoor DC fan motor malfunction L9 Power protection Fo Gathering refrigerant F1 Indoor ambient sensor open or short circuit F2 Indoor tube sensor open or short circuit F3 Outdoor ambient sensor open or short circuit F4 Outdoor tube sensor open or short circuit F5 Exhaust sensor open or short circuit F6 Overload limit / drop frequency F8 Over current limit / drop frequency F9 High exhaust temperature limit / drop frequency F0 Refrigerant leakage protection FH Anti-f...