Voltas Air Conditioner Error Codes

 Voltas Tata Inverter Split AC Error Codes (Model: 20170325) :

Voltas Air Conditioner Error Codes-min
Voltas Air Conditioner Error Codes-min
Error CodesProblem
EEIndoor machine EE fault
E0Outdoor EE fault
E1Indoor fan fault
E2Indoor fan zero-crossing detection abnormal
E3Indoor coil fault and sensor fault
E4Indoor ambient temperature sensor fault
E5Fan Operation Error
E6Indoor and outdoor machine communication fault
E8Outdoor communication fault
F1Compressor starting abnormal
F2Compressor out of step fault
F3IPM module fault
F4Compressor shell roof fault/protection
F5Discharge temperature sensor fault
F6Section temperature sensor fault
F7Outdoor coil temperature sensor fault
F8Outdoor ambient temperature sensor fault
F9Outdoor DC fan fault
P1Outdoor machine AC current protection
P2Compressor phase current protection
P3Outdoor unit over-high or over-low AC voltage protection
P4DC voltage over-high or over-low voltage protection
P5IPM over-high temperature protection
P6Discharge temperature overheat protection
P7Cooling indoor coil anti freezing protection
P8Cooling outdoor coil overheat protection
P9Heating indoor coil overheat protection
PCCooling outdoor ambient temperature over-low protection
PHHeating outdoor ambieent temperature over-high protection
L1Drive bus voltage over-high protection
L2Drive bus voltage over-low protection
L3Drive phase current overload fault
L4Phase current samping abnormal
U1IPM Over current protection
U3Compressor Over current protection
U4Over voltage protection
U5Low voltage protection
U7Over speed protection

Voltas Venture Slimline Tower AC Error Codes (Model: FAC241CZGG):

Its sleek & tall design helps to fit in small spaces. Additionally, it suits the style of your room interiors.

Voltas Venture Slimline Tower AC Error Codes
Voltas Venture Slimline Tower AC Error Codes
Error CodesProblem
E1The trouble of indoor unit room temperature sensor
E2The trouble of indoor unit pipe temperature sensor
E3The trouble of PG motor
E5Wired controller communication failure
E6The EEPRO of indoor unit error
1EThe trouble og outdoor unit room temperature sensor
2EThe trouble of outdoor unit pipe temperatue sensor
3EThe trouble of exhaust sensor
4EThe EEPRO of indoor unit error ( outdoor unit). Replace the module board of outdoor unit
8EThe trouble of PFC. Replace the module board of outdoor unit
H1Automatic defrosting
H3Stop for compressor overload protection
H4Overload protection
H5Stop for IPM module protection
H6PG motor does not operate ( indoor fan motor)
HCPFC overcurrent malfunction
L9High protection of power
LPIndoor and outdoor units cant match with each other
PHHigh voltage protection
PLLow voltage protection
C5Jumper cap malfunction

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

Innovair Air Conditioner Error Codes

 innovair  prestige  inverter mini split system: Innovair Air Conditioner Error Codes Error Codes Problem E2 Anti-freezing protection E3 Block or Low pressure of refrigerant system E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor unit and outdoor unit E8 Anti-high temperature protection H4 Anti-high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection LP Indoor unit and outdoor unit doesn't match L3 Outdoor DC fan motor malfunction L9 Power protection Fo Gathering refrigerant F1 Indoor ambient sensor open or short circuit F2 Indoor tube sensor open or short circuit F3 Outdoor ambient sensor open or short circuit F4 Outdoor tube sensor open or short circuit F5 Exhaust sensor open or short circuit F6 Overload limit / drop frequency F8 Over current limit / drop frequency F9 High exhaust temperature limit / drop frequency F0 Refrigerant leakage protection FH Anti-f...