Toyotomi Portable and Split AC Error Codes

 When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identification of error code.

Toyotomi Portable and Split AC Error Codes
Toyotomi Portable and Split AC Error Codes
Error CodesProblem
E5It can be eliminated after restarting the unit.
E8It can be eliminated after restarting the unit.
U8It can be eliminated after restarting the unit.
H6It can be eliminated after restarting the unit.
C5Please contact qualified professionals for service.
F1Please contact qualified professionals for service.
F2Please contact qualified professionals for service.
Toyotomi Portable and Split AC Error Codes
Toyotomi Portable and Split AC Error Codes

Troubleshooting

Symptom: Unit does not work.

Cause:

  1. Power cut.
  2. The plug has been plugged improperly.
  3. The full-tank indicator is ON. Tank is full.

Solution:

  1. Wait for power to be supplied again.
  2. Plug in again.
  3. Remove the drain water from the drain tank.

Symptom: Unit suddenly stops during in operation.

Cause:

  1. The indoor temperature has reached the set temperature level.
  2. The preset time is up.
  3. The full-tank indicator is ON. Tank is full.

Solution:

  1. Reset the temperature level.
  2. Reset the timer.
  3. Remove the drain water from the drain tank.
Toyotomi AC Remote Control
Toyotomi AC Remote Control

Symptom: Unit runs intermittently.

Cause:

  1. Malfunction.
  2. Surrounding temperature is too high or too low.
  3. Exhaust duct hose is blocked.

Solution:

  1. Contact your dealer.
  2. Check the duct hose.

Symptom: Unit functions but the room is not cooled.

Cause:

  1. Window or door is left open in the room.
  2. There is heat source in the room or too many of people in it.
  3. Air intake grille is clogged.
  4. Filter is too dirty.
  5. Temperature setting is too high.

Solution:

  1. Close all windows and door.
  2. Move out any heat source in the room.
  3. Clean the air intake grille.
  4. Replace the filter.
  5. Lower the temperature setting.

Symptom: Condensed water is spilled out when moving the unit.

Cause: The tank is nearly full.

Solution: Remove the drain plug on the rear bottom of the unit, drain off the water then the unit will be in operation automatically.

Before Calling For Service

The followings are not defects.

A hissing noise or hollow sound ⇒ This sound is generated from the refrigerant flowing within pipes.

A squeaking noise ⇒ This noise is generated from the unit when it is expands or contracts with temperature changes.

Odor ⇒ Such odor as tobacco, cosmetics, or foods may accumulate in the unit.

The unit does not start nor change operation mode immediately ⇒ To prevent overloading the compressor motor, the unit will be stopped for more than 3 minutes.

TAD-24E OPERATING MANUAL PDF

TAD-30K OPERATING MANUAL PDF

TAD-35E OPERATING MANUAL PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condenser Op

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive load on the board. Problem:  NO

York VRF Error Codes

  Malfunction and Protection Code Table. The display board in digital scroll system is just to display running conditions and  malfunction information. The manual button is just to check the address code and power code  of indoor units. York VRF Error Codes Malfunction and Protection Code Table: Error Codes Contents E0 Phase sequence or lack of phase E1 Communication malfunction E2 T1 sensor malfunction E3 T2A sensor malfunction E4 T2B sensor malfunction E5 T3 sensor malfunction E6 Over-zero checking malfunction E7 EEPROM malfunction E8 Fan motor checking out of control E9 Communication malfunction between PCB and Display board EF Other malfunction EE Water level checking malfunction ED Outdoor protection EC Clear malfunction EB Inverter Module Protection EA Compressor Over-current (4 times) P0 Evaporator Temp. Protection P1 Anti-cooling or Defrost Protection P2 Condenser High Temp. Protection P3 Compressor Temp. Protection P4 Discharge Pipe Temp. Protection P5 Discharge High-pressure