 When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identification of error code.

Toyotomi Portable and Split AC Error Codes
Toyotomi Portable and Split AC Error Codes
Error CodesProblem
E5It can be eliminated after restarting the unit.
E8It can be eliminated after restarting the unit.
U8It can be eliminated after restarting the unit.
H6It can be eliminated after restarting the unit.
C5Please contact qualified professionals for service.
F1Please contact qualified professionals for service.
F2Please contact qualified professionals for service.
Toyotomi Portable and Split AC Error Codes
Toyotomi Portable and Split AC Error Codes

Troubleshooting

Symptom: Unit does not work.

Cause:

  1. Power cut.
  2. The plug has been plugged improperly.
  3. The full-tank indicator is ON. Tank is full.

Solution:

  1. Wait for power to be supplied again.
  2. Plug in again.
  3. Remove the drain water from the drain tank.

Symptom: Unit suddenly stops during in operation.

Cause:

  1. The indoor temperature has reached the set temperature level.
  2. The preset time is up.
  3. The full-tank indicator is ON. Tank is full.

Solution:

  1. Reset the temperature level.
  2. Reset the timer.
  3. Remove the drain water from the drain tank.
Toyotomi AC Remote Control
Toyotomi AC Remote Control

Symptom: Unit runs intermittently.

Cause:

  1. Malfunction.
  2. Surrounding temperature is too high or too low.
  3. Exhaust duct hose is blocked.

Solution:

  1. Contact your dealer.
  2. Check the duct hose.

Symptom: Unit functions but the room is not cooled.

Cause:

  1. Window or door is left open in the room.
  2. There is heat source in the room or too many of people in it.
  3. Air intake grille is clogged.
  4. Filter is too dirty.
  5. Temperature setting is too high.

Solution:

  1. Close all windows and door.
  2. Move out any heat source in the room.
  3. Clean the air intake grille.
  4. Replace the filter.
  5. Lower the temperature setting.

Symptom: Condensed water is spilled out when moving the unit.

Cause: The tank is nearly full.

Solution: Remove the drain plug on the rear bottom of the unit, drain off the water then the unit will be in operation automatically.

Before Calling For Service

The followings are not defects.

A hissing noise or hollow sound ⇒ This sound is generated from the refrigerant flowing within pipes.

A squeaking noise ⇒ This noise is generated from the unit when it is expands or contracts with temperature changes.

Odor ⇒ Such odor as tobacco, cosmetics, or foods may accumulate in the unit.

The unit does not start nor change operation mode immediately ⇒ To prevent overloading the compressor motor, the unit will be stopped for more than 3 minutes.

TAD-24E OPERATING MANUAL PDF

TAD-30K OPERATING MANUAL PDF

TAD-35E OPERATING MANUAL PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...