Rheem Pool Heat Pump Error Codes

 

Rheem Pool Heat Pump Error Codes
Rheem Pool Heat Pump Error Codes
Alarm codeDescription
E0probe 1 error (control)
E1probe 2 error (defrost)
E2probe 3 error (cond)
IAexternal alarm
dORopen door alarm
LOlow temperature alarm
HIhigh temperature alarm
EEunit parameter error
EFoperating parameter error
Eddefrost ended by timeout
dFdefrost running
chtdirty condenser pre-alarm
CHtdirty condenser alarm
EtCclock alarm

OFF – The desired programmed temperature point is lower than 60°F (15°C).

LP & LP3 – Shortage of refrigerant gas in the unit or faulty low pressure control. The unit will show (LP3) after 3 LP faults and shuts down the unit and pool pump for protection. If this occurs, you should call for service.

HP & HP6 – Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The unit will show (HP6) after 6 HP faults. This will stop the unit for protection.

FLo & FL3 – Possible causes:

• The filter is in backwash position.
• The filter pump is stopped.
• The filter is dirty.
• Shortage of water to pool pump.
• Water pressure switch must be adjusted or it is broken.
• The unit is in the protection mode and will show (FL3), press any key to restart the unit.
FL3 code will stop the unit and pool pump.

FS – Unit is in the defrosting cycle. (The fan works but the compressor is stopped.)

Rheem Pool Heat Pump Troubleshooting

Rheem Pool Heat Pump Control Panel
Rheem Pool Heat Pump Control Panel

Caution! Any troubleshooting involving electrical or refrigeration must only be carried out by Licensed Persons. Any electrical work is to be undertaken with the unit electrically isolated.

Machine Will Not Start;

As a safety feature, the Heat Pump has a programmed time delay between provision of power and unit start, usually a few minutes. Wait for this time delay before making the following checks:

  • Check electrical supply to the unit is ON.
  • Check phases are in correct rotation (for three phase units only) Red and Green lights lit on Phasefail sequence relay. If red light is lit only this indicates a loss of phase or incorrect
  • Check water flow
  • Check electrical for loose connections and wiring.
  • Check supply fuse.
  • Check thermostat is correctly set.
Rheem Pool Heat Pump Troubleshooting
Rheem Pool Heat Pump Troubleshooting

Pool Will Not Heat;

  • Check that the ejected air temperature is colder than incoming air. Check that the evaporator and internal pipes sweating. This is evidence of heat removal from the air, suggesting that the heater is working.
  • Check inlet louvres, outlet grill and condenser coil has satisfactory airflow and is not clogged.
  • Check that thermostat is correctly set
  • Check that water pump is running
  • Check water filter is operational
  • Check that inlet valves are not closed
  • Check ambient air temperature suits design standards
Rheem Heat Pump Installation, Maintenance PDF
Rheem Heat Pump Installation, Maintenance PDF

Rheem Heat Pump Installation, Maintenance PDF

Rheem Pool Heat Pump Installation PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...