Pridiom Air Conditioner Error Codes

 

Pridiom Air Conditioner Error Codes
Pridiom Air Conditioner Error Codes

 

Note: Above self check information is commonly applicable in our most air conditioners,but some are special, you can refer to the User’s Manual for information or contact the dealer or authorized maintenance people for help.

Error CodesSolution
dFHint to defrosting. Self-check code of luminotron: Flicker 1 time/1s
Fan motor picture not runningHint to defense against cold wind. Flicker 1 time/3s
E2/(L2)Failure of room temperature sensor. Flicker 2 times/4s (Flicker 2 times/8s)
E3/(L1)Failure of coiled pipe sensor. Flicker 3 times/5s (Flicker 1 time/8s)
E4/(E5)Abnormality of outdoor unit. Flicker 4 times/6s (luminating)
E5/(L6)Without feedback of internal fan motor. Flicker 5 times/7s (Flicker 6 times/8s)
E6Zero crossing signal without current. Flicker 6 times/8s
E7External feedback failure. Flicker 7 times/9s
E8Overheat protection. Flicker 8 times/10s
E9Water pump failure. Flicker 9 times/11s
F1Communicate fault
F2Room temp. sensor fault
F3Temp. sensor of coil pipe outlet fault
F4Fan motor fault
P2Transducer module protection
P3Over current
P4Discharge temperature of compressor overheat, ambient temperature overheat
P7DC voltage of outdoor unit abnormal
P8Leakage or reverse valve fault
F6Outdoor sensor fault
FCCompressor drive fault

Inspection and Maintenance

  • According to the service conditions and operating environment , the inside of the air conditioner will become dirty after several seasons (3 to 5years ) of service , resulting in decreased operating performance .Inspection and maintenance are recommended in addition to usual cleaning (The air conditioner can be used for a longer period and without anxiety .)
  • As to inspection and maintenance , consult your dealer or any one of business offices of dealing companies .(Service charge is required in this case .)
  • We recommend to perform inspection and maintenance during an off seasons.

Selection of installation positions for outdoor unit

  • To install the outdoor unit at the places which can stand the load of the machine weight and will not cause big vibrations and noises;
  • To install the unit at the places not to be exposed to rain or direct sunshine, and the places with good ventilation;
  • The noises generated from the unit will not affect the neighboring places;
  • Do not install the unit on non-metal frame;
  • Not to install the unit at the places where there might occur the generation, inflow, stay or leakage of inflammable gases;
  • Pay attention to the drainage of the condensed water from the base plate during operations;
  • To avoid the air outlet being directly against the wind.

AOS090HR  120HR outdoor wire diagram

AOS090HR 120HR outdoor wire diagram
AOS090HR 120HR outdoor wire diagram

Operation and indication sections of remote controller

This remote controller is the general one used for many types of air-conditioner in our company,we beg your forgiveness that we would not introduce the button or indicator which is not applicable for units you purchased.The LAMP button is applicable for special latest developed new models only instead of normal models.

Operation and indication sections of remote controller
Operation and indication sections of remote controller
  • Above figure shows all indications for the purpose of explanation, but practically only the pertinent parts are indicated.When air-conditioner is cooling-only model, the HEAT is for FAN.
  • When TURBO operation is selected, room temperature is not controlled with operation being continually.If you feel the room temperature is too cool or too heat,please cancel the TURBO operation.

Defrosting

When the outdoor air temperature is very low and humidity is very high, frosting will occur to the heat exchanger of the outdoor unit, which has negative impacts upon the efficiency of the heating performance. In such case, the automatic defrosting function will come into play. The heating operation will be stopped for 5-10 minutes to do the defrosting.

  • The fans of both the outdoor and indoor units are stopped.
  • During the defrosting, the outdoor unit might generate some steam. It is caused by fast defrosting, which is not a performance failure.
  • Upon the completion of the defrosting process, the heating operation is resumed.

Pridiom Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

Innovair Air Conditioner Error Codes

 innovair  prestige  inverter mini split system: Innovair Air Conditioner Error Codes Error Codes Problem E2 Anti-freezing protection E3 Block or Low pressure of refrigerant system E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor unit and outdoor unit E8 Anti-high temperature protection H4 Anti-high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection LP Indoor unit and outdoor unit doesn't match L3 Outdoor DC fan motor malfunction L9 Power protection Fo Gathering refrigerant F1 Indoor ambient sensor open or short circuit F2 Indoor tube sensor open or short circuit F3 Outdoor ambient sensor open or short circuit F4 Outdoor tube sensor open or short circuit F5 Exhaust sensor open or short circuit F6 Overload limit / drop frequency F8 Over current limit / drop frequency F9 High exhaust temperature limit / drop frequency F0 Refrigerant leakage protection FH Anti-f...