 GE Air Conditioner Fault Codes List:

General Electric Air Conditioner Error Codes
General Electric Air Conditioner Error Codes
Error CodesProblem-Repair
E0On 70 Pint models only - when water is not pumped out while the unit is running under the Pump mode, E0 and the pump light will flash on the display.
E1Electronic control board function error. Unplug the window air conditioner for 1 minute and then plug it back in to reset the electronic control board. If the code doesn’t clear, unplug the window air conditioner and check the wire harness connections on the electronic control board. Check the electronic control board for visible damage such as a burn mark. Replace the electronic control board if it’s damaged or defective.
E4Water bucket is full or defective bucket float switch. If the collection bucket is full, empty the bucket. If the bucket isn’t full, unplug the air conditioner and check the wire harness connections on the electronic control board. Check for a pinched or damaged wire in the wire harness between the electronic control board and the collection bucket float switch. Check the float switch for damage. If the float switch is defective, replace it.
88When power is connected to the unit, "88" will be displayed, this is normal. If a fault or error code appears on the display of the dehumidifier, disconnect power to the unit for 30 seconds. If the fault code reappears, review the Troubleshooting Tips in your Owner's Manual.

Troubleshooting Tips

Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.

Problem: Air conditioner does not start

Possible Causes:

  1. The air conditioner is unplugged.
  2. The fuse is blown/circuit breaker is tripped.
  3. Power failure.
  4. The current interrupter device is tripped.

What To Do:

  1. Make sure the air conditioner plug is pushed completely into the outlet.
  2. Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
  3. If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the com pressor overload.
  4. Press the mESEI’button located on the power cord plug.

 

GE Window Air Conditioner Error Codes
GE Window Air Conditioner Error Codes

 

Problem: Air conditioner does not cool or heat as it should

Possible Causes:

  1. Airflow is restricted.
  2. The temp control may not be set correctly.
  3. The air filter is dirty.
  4. The room may have been hot.
  5. Cold air is escaping.
  6. Cooling coils have iced up.

What To Do:

  1. Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner.
  2. ln COOL mode or HEAT mode (some models), press the DECREASE- pad.
  3. Clean the filter at least every 30 days,
  4. When the air conditioner is first turned on, you need to allow time for the room to cool down.
  5. Check for open furnace registers and cold air returns,
  6. See “Air conditioner freezing up”below.

Problem: Air conditioner freezing up

Possible Causes: Ice blocks the airflow and stopsthe air conditioner from cooling the room.

What To Do:

  1. Set the controls at HIGH FAN or HIGH COOL and set the thermostat to a higher temperature to allow the ice to melt.
  2. Check filter for cleanliness.

Problem: The remote control is not working

Possible Causes:

  1. The batteries are inserted incorrectly.
  2. The batteries may be dead.

What To Do:

  1. Check the position of the batteries, They should be inserted correctly.
  2. Replace the batteries,

Problem: Water drips outside

Possible Causes: Hot, humid weather.

What To Do: This is normal.

Problem: Water drips indoors

Possible Causes: The air conditioner is not tilted to the outside.

What To Do: For proper water disposal, make sure the air conditioner case is level or slants slightly from the case from to the rear.

Problem: Water collects in basepan

Possible Causes: Moisture removed from air and drains into base pan.

What To Do: This is normal for 0 short period in areas with little humidity; normal for a longer period in very humid areas.

General Electric Air Conditioner Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...