Skip to main content

Fujitsu General VRF Error Codes

 Airstage V2  Series, Multi AC System for Buildings.

Error Code List for Outdoor Unit:

Fujitsu General VRF Error Codes
Error CodesProblem
- - - -Initial Setting Error
1 3 . 1Communication Error Between Outdoor Unit
1 4 . 1Outdoor Unit Network communication 1 Error
1 4 . 2Outdoor Unit Network communication 2 Error
2 8 . 1Auto Address Setting Error
2 8 . 4Signal Amplifier Auto Address Setting Error
5 U . 1Indoor Unit Error
6 1 . 5Outdoor Unit Reverse Phase, Missing Phase Wire Error
6 2 . 3Outdoor Unit EEPROM Access Error
6 2 . 6Inverter Communication Error
6 2 . 8Outdoor Unit EEPROM Data Error
6 3 . 1Inverter Error
6 7 . 2Inverter PCB Momentary Power Failure Detection
6 8 . 1Magnetic Relay Error
6 8 . 2Rush Current Limiting Resistor Temp Rise Protection
6 9 . 1Outdoor Unit Communication PCB Parallel Communication Error
7 1 . 1Discharge Temp Sensor 1 Error
7 1 . 2Discharge Temp Sensor 2 Error
7 2 . 1Compressor Temp Sensor 1 Error
7 2 . 2Compressor Temp Sensor 2 Error
7 3 . 3Outdoor Unit Heat Ex. Liquid Temp. Sensor Error
7 4 . 1Outdoor Temp Sensor Error
7 5 . 1Suction Gas Temp Sensor Error
7 7 . 1Heat Sink Temp Sensor Error
8 2 . 1Sub-cool Heat Ex. Gas Inlet Temp. Sensor Error
8 2 . 2Sub-cool Heat Ex. Gas Outlet Temp. Sensor Error
8 3 . 1Liquid Pipe Temp. Sensor 1 Error
8 3 . 2Liquid Pipe Temp. Sensor 2 Error
8 4 . 1Current Sensor 1 Error
8 6 . 1Discharge Pressure Sensor Error
8 6 . 3Suction Pressure Sensor Error
8 6 . 4High Pressure Switch 1 Error
8 6 . 5High Pressure Switch 2 Error
9 2 . 1Compressor 2 Error
9 2 . 2Compressor 2 Current Value Error
9 3 . 1Inverter Compressor Start Up Error
9 4 . 1Trip Detection
9 5 . 5Compressor Motor Loss of Synchronization
9 7 . 1Outdoor Unit Fan Motor Lock Error
9 7 . 4Outdoor Unit Fan Motor Undervoltage
9 7 . 5Outdoor Unit Fan Motor Temperature Abnormal
9 U . 2Slave Unit Error
A 1 . 1Discharge Temperature 1 Abnormal
A 2 . 1Discharge Temperature 2 Abnormal
A 3 . 1Compressor 1 Temperature Abnormal
A 3 . 2Compressor 2 Temperature Abnormal
A 4 . 1High Pressure Abnormal
A 4 . 2High Pressure Protection 1
A 4 . 3High Pressure Protection 2
A 5 . 1Low Pressure Abnormal
A C . 4Heat Sink Temperature Abnormal
Fujitsu General VRF Advanced High Efficiency Technology
Fujitsu General VRF Advanced High Efficiency Technology

Error Code List for Simple and Wired Remote Controller

Fujitsu General Wired Remote Controller
Fujitsu General Wired Remote Controller
Error CodesError Contents
1 2Remote Controller Communication Error
1 4Network Communication Error
1 5Scan Error
1 6Indoor Unit Parallel Communication Error
3 1
Indoor Unit Power Frequency Abnormal
3 2
Indoor Unit Main PCB Error
4 1
Room Temperature Sensor Error
4 2Indoor Unit Heat Ex. Sensor Error
5 1Inddor Unit Fan Motor Error
5 3Water Drain Abnormal
9 UOutdoor Unit Error
Central Control of Small Office
Central Control of Small Office

Error Code List for Group Remote Controller

Fujitsu General Remote Controller
Fujitsu General Remote Controller
Error CodesMeaning
- -Initial Setting Error
1 2Remote Controller Communication Error
1 3Communication Error Between Outdoor Unit
1 4Network Communication Error
1 5Scan Error
1 6Indoor Unit Parallel Communication Error
2 6Address Setting Error
2 8Other Setting Error
3 1Indoor Unit Power Frequency Abnorma
3 2Indoor Unit Main PCB Error
4 1Room Temperature Sensor Error
4 2Indoor Unit Heat Ex. Sensor Error
5 1Inddor Unit Fan Motor Error
5 3Water Drain Abnormal
6 1Outdoor Unit Reverse Phase, Missing Phase Wire Error
6 2Outdoor Unit Main PCB Error
6 3Inverter Error
6 7Inverter PCB Momentary Power Failure Detection
6 8Magnetic Relay Error
6 9Outdoor Unit Communication PCB Error
7 1Discharge Temperature Sensor Error
7 2Compressor Temperature Sensor Error
7 3Outdoor Unit Heat Ex. Temperature Sensor Error
7 4Outdoor Temperature Sensor Error
7 5Suction Gas Temperature Sensor Error
7 7Heat Sink Temperature Sensor Error
8 2Sub-cool Heat Ex. Gas Temperature Sensor Error
8 3Liquid Pipe Temperature Sensor Error
8 4Current Sensor Error
8 6Pressure Sensor Error
9 2Compressor 2 Error
9 3Compressor Start Up Error
9 4Trip Detection
9 5Compressor Motor Control Error
9 7Outdoor Unit Fan Motor Error
A 1Discharge Temperature 1 Abnormal
A 2Discharge Temperature 2 Abnormal
A 3Compressor Temperature Abnormal
A 4High Pressure Abnormal
A 5Low Pressure Abnormal
A CHeat Sink Temperature Abnormal
C 4PCB Error
C ASoftware Error
C 1PCB Error 1
Individual and Central Control of Large Homes
Individual and Central Control of Large Homes
Fujitsu General VRF Error Codes
Fujitsu General VRF Error Codes

 

Fujitsu General Airstage V2  Series Manual PDF

fujitsu-general.com

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...