Fedders Air Conditioner Error Codes

 Upon receipt of equipment, check carton for visible damage. Make a notation on the shipper’s delivery ticket of any damages before signing.

If there is any evidence of rough handling, the cartons should be  opened at once to check for concealed damage. If any damage is found, notify the carrier within 48 hours to establish your claim, and request an inspection report from the carrier. The warranty claims department should then be contacted.

Fedders Air Conditioner Error Codes
Fedders Air Conditioner Error Codes
Error CodesCause
E1System high pressure protection
E2Anti-freezing protection
E4Compressor air exhaust high temp. protection
E5AC overload protection
E6Indoor and outdoor units communication malfunction
E8Anti-high temp. protection
H6Indoor unit motor no feedback
C5Jump wire cap malfunction protection
F1Indoor ambient sensor open circuit, short circuit
F2Indoor evaporator sensor circuit open, short circuit
F3Outdoor ambient sensor circuit open, circuit short
F4Outdoor condensor sensor open circuit, short circuit
F5Outdoor air exhaust sensor open circuit, short circuit
F6Overload limit/descending frequency
F8Over current need frequency descending
F9Air exhaust over high need frequency descending
PHDC generatrix voltage is too high
U5Whole unit’s current testing malfunction
P5Compressor current overcurrent protection
H1Defrosting
H2Electrostatic dedust protection
H3Compressor overload protection
H4System is abnormal
H5IPM protection
HCPFC protection
H7Compressor lose steps
H0Heating, anti-high temp. declines
LcStartsup fail
U1Compressor current testing circuit malfunction
EEEEPROM malfunction
PUCapacitor charge malfunction
P7Module sensor circuit diagram
P8Module temp. over high protection
U3DC Bus voltage dips
PLLow DC Bus voltage protection
EUIPM temp. is too high limit/decrease frequency
U7Four-way valve abnormal
U9Outdoor unit zerocross detecting error
FHAnti-freezinglimit/decreasefrequency

FEDDERS LARGE SPLIT UNIT (R407C)

Fedders Wall Air Conditioners-Heat Pumps-F1-F2-F3-F4-HP-C-EH-HD
Fedders Wall Air Conditioners-Heat Pumps-F1-F2-F3-F4-HP-C-EH-HD

Fedders Air Conditioner Troubleshooting

Fedders Air Conditioner Troubleshooting
Fedders Air Conditioner Troubleshooting

Air conditioner will not operate

Possible Cause:

  1. Wall plug disconnected.
  2. House fuse blown or circuit breaker tripped.
  3. Unit turned off and then on too quickly.
  4. Thermostat set too low for cooling.

Solutions:

  1. Push plug firmly into wall outlet.
  2. Replace fuse with time delay type or reset circuit breaker.
  3. Wait 3 minutes before restarting.
  4. Adjust thermostat to lower temperature

Air from unit does not feel cold enough

Possible Cause:

  1. Unit in Fan mode.
  2. Temperature set too high.
  3. Room temperature below 70°F

Solutions:

  1. Set Mode to Cool.
  2. Set thermostat to lower temperature.
  3. Cooling may not occur until room temperature rises above 70°F.

Air conditioner cooling, but room is too warm ice forming on cooling coil behind decorative front

Possible Cause:

  1. Outdoor temperature below 70°F.
  2. Dirty air filter air restricted.

Solutions:

  1. To defrost the coil, set mode to Fan. Then, set thermostat to warmer temperature.
  2. Clean filter.

Air conditioner cooling, but room too warm –  NO ice forming on cooling coil behind decorative front

Possible Cause:

  1. Dirty air filter air restricted.
  2. Thermostat set too warm.

Solutions:

  1. Clean air filter.
  2. Set thermostat to colder temperature.

Noise when unit is cooling

Possible Cause:

  1. Air movement sound.
  2. Sound of fan hitting watermoisture removal system.
  3. Window vibration poor installation.

Solutions:

  1. The sound of rushing air is normal. If too loud, Fan Speed to Low setting.
  2. This is normal when humidity is high. Close doors, windows and registers.
  3. Refer to installation instructions check with installer

Fedders Air Conditioner Manual PDF


Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

LG VRF Error Codes – Multi V

  Error Codes; Indicate different types of unit failures, assist in self-diagnosis and to track the frequency of occurrence. Error codes are shown on the LED of indoor units, wired remote controller, the outdoor unit control board, and on the main screen of the LG Monitoring View (LGMV) Diagnostic Software. If two or more errors occur simultaneously, the lower error code number is displayed first. After error is resolved, the error code does not display. Error Display; The first, second, and third number on the LED indicates error number; the fourth number on LED indicates outdoor unit number. Examples: 211 = Error No. 21 on master unit, 213 = Error No. 21 on slave2 unit, Error No. 105 on master unit on compressor 1. Error Code Nomenclature Definitions; MICOM: Non-volatile memory chip where unit setup information is stored. EPROM: Non-volatile memory chip where device identification, size, and factory defined default component operating parameters are stored.   LG Multi V Erro...