Skip to main content

Della Portable Air Conditioner Error Codes

 Della Portable Air Conditioner Error Codes, Troubleshooting and Manuals;

Della Portable Air Conditioner Error Codes
Della Portable Air Conditioner Error Codes
Error CodesPossible Causes
CH01Room temperature sensor failure. Check the room temperature sensor and related circuits.
CH02Tube temperature sensor failure. Check the tube temperature sensor and related circuits.
E1Tube temperature sensor failure. Check the tube temperature sensor and related circuits.
E2Room temperature sensor failure. Check the room temperature sensor and related circuits.
E4Anti-freeze protection. Restore the functions automatically once anti-freeze protection is over.

Della Portable Air Conditioner Problems And Solutions;

Problem: The unit does not start when pressing on/off button

Possible Causes:

  1. Water full indicators blinks and water tank is full
  2. Room temperature is higher than the set temperature
  3. Room temperature is lower than the setting temperature

Corrective Action:

  1. Drain the water from the water tank
  2. Reset the temperature
  3. Reset the temperature

Problem: Not cool enough

Possible Causes:

  1. The doors or windows are not closed
  2. There are heat sources inside the room
  3. Exhaust air hose is not connected or blocked
  4. Temperature setting is too high
  5. Air inlet is blocked

Corrective Action:

  1. Make sure all the windows and doors are closed
  2. Remove the heat sources if possible
  3. Connect or clean the exhaust air hose
  4. Reset the temperature
  5. Clean the air inlet and filters
Della Portable Air Conditioner Problems And Solutions
Della Portable Air Conditioner Problems And Solutions

Problem:  The unit is noisy/loud

Possible Causes:

  1. The ground is not level or not flat enough
  2. The sound comes from the flowing of the refrigerant inside the air conditioner

Corrective Action:

  1. Place the unit on a flat, level ground if possible
  2. It is normal

Problem:  The compressor does not seem to be working

Possible Causes: The overheat protection may be activated

Corrective Action: Wait 30 minutes until the temperature has decreased, then turn on the unit again

Problem: The remote control does not function

Possible Causes:

  1. Remote control signal is not detected by the control panel
  2. Distance too great
  3. The batteries are drained

Corrective Action:

  1. Wait 30 minutes until the temperature has decreased, then turn on the unit again
  2. Wait 30 minutes until the temperature has decreased, then turn on the unit again
  3. Check batteries on the remote

Problem: Displays is full

Possible Causes: Water tank in chassis is full

Corrective Action: Drain the condensate and re-start the unit

Della Portable Air Conditioner Parts List
Della Portable Air Conditioner Parts List

Della Portable AC Manual PDF 1

Della Portable AC Manual PDF 2

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...