 Some issues can be resolved without any maintenance to the unit, check the chart below to see if there is a suggested solution to the problem before calling for service.

Comfortaire AC Error Codes and Troubleshooting
Comfortaire AC Error Codes and Troubleshooting

 

Glossary of Error Codes and Their Meanings:

Error CodesMeaning
E1High Pressure Protection
E2Shutdown for Whole Unit AntiFreeze Protection
E3Low Pressure Protection
E4High Discharge Temp Protection
E6Communication Error
E9Indoor Unit Water Full Error
FoRefrigerant Recovery Mode
F3Outdoor Ambient Temp Sensor Error
F4Outdoor Mid-Coil Temp Sensor Error
F5Outdoor Discharge Air Temp Sensor Error
F7Oil Return for Cooling
H1Forced Defrosting
H2Oil Return for Heating or Defrosting
H3Compressor Overheat Protection
H5IPM Protection
H7Motor Desynchronizing
HcPFC Error
LcStartup Failure
LADC Fan motor Error
LdPhase Loss
LECompressor Stalling
LFOver-Speed
P0IPM Reset
P5Compressor Current Protection
P6Communication Error between the Inverter Drive and the Main Controller
P7Radiator Temp Sensor Error
P8Radiator Overheat Protection
P9AC Contactor Protection
PcCurrent Sensor Error
PdSensor Connection Protection
PHOver Voltage Protection
PLLow Voltage Protection
PETemp Drift Protection
PFDrive Board Ambient Temp Sensor Error
PAAC Current Protection
PUCharging Circuit Error
PPAC Input Voltage Anomaly

Troubleshooting

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.

Problem: The unit will not operate at all.

Cause:

  1. Blown Fuse or tripped circuit breaker
  2. Power Failure
  3. Remote Control batteries are low
  4. Signal from remote control is not being sent

Solution:

  1. Check the fuse or circuit breaker. Replace the blown fuse or reset the circuit breaker.
  2. Wait until the power is restored to restart the unit. If you experience brown out conditions, contact an electrician or your local utility.
  3. Replace the batteries. Be sure not to mix old and new batteries, as well as different brands/types
  4. Be sure that you are not using the remote control too far away from the indoor unit’s control panel.

Problem: The unit runs and then stops immediately

Cause: Air inlets and/or outlets are blocked

Solution: Remove any obstacles from the air inlets/outlets/Clean the air filter, louvers, and inlet grille.

Problem: Abnormal heating or cooling

Cause:

  1. Air inlets and/or outlets are blocked
  2. Improper temperature is set
  3. Check the fan speed
  4. Improper louver adjustment
  5. Be sure that there are no other sources of heat/steam in the area being cooled
  6. Conditioned air might be escaping

Solution:

  1. Remove any obstacles from the air inlets/outlets-Clean the air filter, louvers, and inlet grille.
  2. Ensure that the proper mode and temperature is set on the unit. Try to adjust the set point temperature on the thermostat to a better operating temperature
  3. Adjust the fan speed to see if that improves the conditions.
  4. Try to adjust the louver position to ensure it is open enough.
  5. Remove or turn off other appliances producing heat or steam.
  6. Ensure that any doors or windows in the area being heated/cooled are closed

Problem: Air from unit does not feel cold enough

Solution:

  1. Room temperature below 62 F(17 C ). Cooling may not occur until room temperature O O rises above 62 F(17 C).
  2. Temperature sensing behind air filter element touching cold coil. Keep it from the cold coil.
  3. Set to a Lower temperature.
  4. Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode.

Problem: Noise when unit is cooling

Solution:

  1. Air movement sound. This is normal . If too loud, set to a slower FAN setting.
  2. Window vibration – poor installation. Refer to installation instructions or check with installer.
Comfort Aire Mini Split Ductless Air Conditioners Error Codes
Comfort Aire Mini Split Ductless Air Conditioners Error Codes

 

After power on, LED3 (Green color) and LED2 (Red color) will be flash if the unit has some
After power on, LED3 (Green color) and LED2 (Red color) will be flash if the unit has some
Table-4-Meaning-of-Each-Error
Table-4-Meaning-of-Each-Error
Table-4-Meaning-of-Each-Error2
Table-4-Meaning-of-Each-Error2

COMFORT-AIRE BG-81P Owner’s Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

Innovair Air Conditioner Error Codes

 innovair  prestige  inverter mini split system: Innovair Air Conditioner Error Codes Error Codes Problem E2 Anti-freezing protection E3 Block or Low pressure of refrigerant system E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor unit and outdoor unit E8 Anti-high temperature protection H4 Anti-high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection LP Indoor unit and outdoor unit doesn't match L3 Outdoor DC fan motor malfunction L9 Power protection Fo Gathering refrigerant F1 Indoor ambient sensor open or short circuit F2 Indoor tube sensor open or short circuit F3 Outdoor ambient sensor open or short circuit F4 Outdoor tube sensor open or short circuit F5 Exhaust sensor open or short circuit F6 Overload limit / drop frequency F8 Over current limit / drop frequency F9 High exhaust temperature limit / drop frequency F0 Refrigerant leakage protection FH Anti-f...