Blueridge AC Error Codes and Troubleshooting

 

Blueridge Mini Split Error Codes
Blueridge Mini Split Error Codes

This unit has onboard diagnostics. Error codes will appear on the LED display on the front panel of the indoor unit in place of the temperature display. The table below explains the error codes for both units.

Error CodesSolution
C5Indoor Configuration Jumper. Missing Configuration Jumper on Indoor Control Board.
LPIndoor/Outdoor Mismatch. Indoor and Outdoor Units Do Not Match (Model or Capacity.
PLLow voltage.
E1High pressure protection.
E5High Current Protection. Power Supply is not Stable and Voltage Range is too Large.
E6Communication Error. check the connection. Mis-wired or Communication Failure.
E7(Multizone only) Mode Conflict.
F0Gathering Refrigerant / Unit is low on refrigerant (Leak).
F1Indoor Air Temp. Thermistor. Bad Connection, or Indoor Air Sensor Failure.
F2Indoor Coil Temp. Thermistor. Bad Connection, or Indoor Coil Sensor Failure.
F3Outdoor Air Temp. Thermistor. Bad Connection, or Outdoor Ambient Sensor Failure.
F4Outdoor Coil Temp. Thermistor. Bad Connection, or Outdoor Coil Sensor Failure.
F5Compressor Discharge Temp. Thermistor. Bad Connection, or Discharge Sensor Failure.
H1Means defrosting status. It’s the normal phenomenon.
H3Compressor Overload Protection. Low Refrigerant Charge, Blocked Capillary, or Compressor Motor Failure.
H4It can be eliminated after restarting the unit. If not,please contact qualified professionals for service.
H5IPM Module Protection. IPM Module Temperature Too High, High Ambient, Low Voltage, or Bad Connections.
H6Indoor Fan Malfunction. Indoor Fan Stopped or Running too Slow.
H7Compressor Synchronism. High Pressure, Low Voltage, or Bad Connections.
U74-Way Valve Malfunction. Bad Connection, Solenoid Failure, or Valve Malfunction. ( Heat Pumps Only)
U8It can be eliminated after restarting the unit. If not,please contact qualified professionals for service.
Blueridge AC Indoor Parts Meaning
Blueridge AC Indoor Parts Meaning

Cleaning and Maintenance

  1. Pull up on the front left and right of the air handler’s cover as shown in figure 1
  2. Remove the filter as indicated in figure 2. There are two filters, one on each side. Press up on the middle tab on each filter to take it out.
  3. Use dust catcher or water to clean. When the filter is very dirty, the water (below 113oF) to clean it, and then put it in a shady and cool place to dry.
  4. Reinstall the filter making sure the filter’s two tabs are in the correct place and the middle of the filter is secured underneath the white tab, then close the panel cover.
Blueridge AC Ductless Mini Split Cleaning and Maintenance
Blueridge AC Ductless Mini Split Cleaning and Maintenance

The indoor air handler’s filter should be cleaned every three months, but may require cleaning more often based on the conditions of the room. It is not harmful to increase the cleaning frequency.

Use caution after the filter has been removed. The fins of the evaporator coil will be exposed and are very sharp. Do not touch the fins, as touching the fins can cause injury as well as a decrease in the unit’s performance.

Blueridge Mini Split Troubleshooting

Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals.

TroubleCause
Indoor unit can’t receive remote controller’s signal or remote controller has no action.Whether it's interfered severely (such as static electricity, stable voltage)? Cut off the power supply. Turn on the power after about 3 minutes turn on the unit again.
Whether remote controller is within the signal receiving range? Signal receiving range is 8m.
Whether there are obstacles? Remove obstacles.
Whether remote controller is pointing at the receiving window? Select proper angle and point the remote controller at the receiving window on indoor unit.
Is sensitivity of remote controller low; fuzzy display and no display? Check the batteries. If the power of batteries is too low, please replace them.
No display when operating remote controller? Check whether remote controller appears to be damaged. If yes, replace it.
Fluorescent lamp in room? 1.Take the remote controller close to indoor unit. 2.Turn off the fluoresent lamp and then try it again.
Air conditioner can’t operatePower failure? Wait until power recovery.
Air switch trips off or fuse is burnt out? Ask professional to replace air switch or fuse.
Wiring has malfunction? Ask professional to replace it.
Unit has restarted immediately after stopping operation? Wait for 3min, and then turn on the unit again.
Whether the function setting for remote controller is correct? Reset the function.
Mist is emitted from indoor unit’s air outletIndoor temperature and humidity is high? Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
No air emitted from indoor unitAir inlet or air outlet of indoor unit is blocked? Eliminate obstacles.
Under heating mode, indoor temperature is reached to set temperature? After reaching to set temperature, indoor unit will stop blowing out air.
Heating mode is turned on just now? In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
Set temperature can’t be adjustedUnit is operating under auto mode? Temperature can’t be adjusted under auto mode. Please switch the operation mode if you need to adjust temperature.
Your required temperature exceeds the set temperature range? Set temperature range: 16℃ ~30℃ .
Cooling (heating) effect is not good.Voltage is too low? Wait until the voltage resumes normal.
Filter is dirty? Clean the filter.
Set temperature is in proper range? Adjust temperature to proper range.
Door and window are open? Close door and window.
Odours are emittedWhether there’s odour source, such as furniture and cigarette, etc. 1.Eliminate the odour source. 2.Clean the filter.
Air conditioner operates normally suddenlyWhether there’s interference, such as thunder, wireless devices, etc. Disconnect power, put back power, and then turn on the unit again.
Outdoor unit has vaporHeating mode is turned on? During defrosting under heating mode, it may generate vapor, which is a normal phenomenon.
“Water flowing” noiseAir conditioner is turned on or turned off just now? The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.
Cracking noiseAir conditioner is turned on or turned off just now? This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
Blueridge AC Outdoor Unit Wire Connections
Blueridge AC Outdoor Unit Wire Connections

Child lock function: Press the “+” and “-” buttons simultaneously to turn on or turn off the child lock function. When the child lock function is started up, LOCK indicator on remote controller is ON. If any buttons are pressed while the lock indicator is ON, the remote controller will not send the signal.

Emergency Operation (Lost Remote): If the remote control is lost or damaged, the heat pump can be turned on and off by using the AUX button. The AUX button is located underneath the front panel on the right hand side. When the AUX button is pressed, the system will run in auto mode. In auto mode, the system will run off of optimal conditions based on the ambient temperature, and the temperature cannot manually be adjusted. The temperature settings are 77oF for cooling and 68oF for heating.

Blueridge Air Conditioner Remote Control Button Meaning
Blueridge Air Conditioner Remote Control Button Meaning

Blueridge Split Type Wall-mounted Air Conditioner Owner’s Manual PDF

Comments

Popular posts from this blog

Rittal Air Conditioner Error Codes

  System messages are shown on the display screen of the Comfort controller via the displays A1 to A20 and E0. Rittal Air Conditioner Error Codes Error Codes System message Possible cause A1 Enclosure door open Door open or door limit switch incorrectly positioned A2 Internal temperature of enclosure too high Cooling capacity inadequate/unit undersized. Error as a consequence of messages A03 to A17. A3 Filter monitoring Filter mat soiled A4 Ambient temperature too high/too low Ambient temperature outside of admissible operating range (+10°C to +60°C) A5 Icing hazard Operational display in case of icing hazard. A6 PSAH pressure-operated switch Ambient temperature too high A7 Evaporator coil Lack of coolant; sensor in front of or behind condenser defective. A8 Condensate warning Condensate discharge kinked or blocked A9 Condenser fan blocked or defective Blocked or defective A10 Evaporator fan blocked or defective Blocked or defective A11 Compressor Compressor overloaded A12 Condense...

Midea VRF Error Codes

  R410A All DC Inverter V4 Plus R Series 50/60Hz Error Codes: V4 VRF:  Advanced 3-pipe technology enables  heat recovery  between indoor units for unprecedented economy and performance. It can simultaneously operate in cooling and heating mode when it is necessary to provide more freedom for operation. It compensates and adjusts when there are hot and cold rooms in the same building, depending on the direction of sunshine. As a result, it reduces annual power consumption. Midea VRF Error Codes Error Codes Problem E0 Communication error between outdoor units. Only display on the faulty slave unit, all the ODUs are in standby. E1 Phase sequence error. Display on the faulty unit, all the ODUs are in standby. E2 Communication error between indoors and the master unit. Only display on the master unit, all the ODUs are in standby. E4 Outdoor ambient temperature sensor (T4) and condenser pipe temperature sensor (T3/T5) error. Display on the faulty unit, all the ODUs are in ...

York Chiller Error Codes and Troubleshooting

  Real Time Error Numbers York Chiller Error Codes and Troubleshooting Error Description 0 All Ok 1 Datum Type Ok Test Failed 2 English Text Too Long 3 Floating Point Exception 4 Get Packet Failed 5 Get Type Failed 6 Invalid Unit Conversion 7 Invalid Hardware Selection 8 Real Time Fault 9 Spanish Text Too Long 10 Thread Exited 11 Thread Failed 12 Thread Stalled 13 Io Board Reset 14 Bram Invalid 15 Bacnet Setup Failed Problem:  No display on panel – unit will not start Possible Cause: Main supply to control system OFF. Emergency stop device off. CB3 tripped. No supply to – T2 No 24VAC supply to power board. No +12V output from powerboard. Action: Switch on main supply if safe to do so. Check if control panel emergency stop switch and any remote emergency stop devices are in the OFF position. Turn to ON position (1) if safe to do so. Check CB3 Check 115VAC to L & 2. Check wiring from – T2 to powerboard and fuse. Replace powerboard or isolate excessive loa...